12
®
The colon that separates hours and minutes blinks once per second when the
display is indicating real time such as elapsed Surface Time, Elapsed Dive
Time, or Time of Day. Dive Time Available, Dive Time Remaining, Decom-
pression Stop Time, Total Ascent Time required, Time to Fly, or Desaturation
Time are calculated projections of time and use a solid (non-blinking) colon to
indicate that they are counting down, rather than up.
Depth and Time displays will be illustrated and described in more detail as ap-
plicable for each of the operating modes.
Temperature Displays
Ambient Temperatures from 0
°
to 99
°
F (-9 to 60
°
C) are displayed together with
date and time (Fig. 12) when the Advance (Left) button is pressed while in the
Surface Mode or a dive mode (described later).
AUDIBLE ALARM
During situations that may pose potential danger, one Double Beep is emit-
ted. These situations are:
• Entry into decompression.
• Decreasing to 5 minutes of Breathing Gas Dive Time Remaining.
• Partial pressure of oxygen equal to or greater than 1.40 ATA.
Fig. 12 - Temperature Dis-
play (on surface)
NO DECO
C Z
DECO
C Z
O
2