22
®
NO DECO
C Z
DECO
C Z
O
2
FT
MAX
TO SET: AUDIBLE ALARM ON/OFF
'OFF' - if the unit senses a condition that poses immediate danger (page 13), it
emits a double beep. Other alarms are silenced
'ON' - alarms will be sounded for all conditions as listed on pages 12 and 13.
• press BOTH buttons simultaneously, while in Surface Mode
• press Advance (Left) button 1 time
• the Audible Alarm icon appears with 'On', or 'Off', flashing (Fig. 18)
• press Select (Right) button to toggle between 'On' and 'Off'
• press Advance (Left) button to accept the setting displayed, and either -
• revert to Surface Mode (if this setting was changed), or -
• advance to Set:Depth Alarm (this setting was not changed)
TO SET: DEPTH ALARM SET POINT
The Depth Alarm can be set to values between 30 feet (10 meters) and 320 feet
(97.5 meters) in 10 foot (3/3.5 meter) increments.
• press BOTH buttons simultaneously, while in Surface Mode
• press Advance (Left) button 2 times
• Max Depth and Audible Alarm icons appear with the Max Depth value
flashing (Fig. 19)
Fig. 18 - Set Audible Alarm
On/Off
Fig. 19 - Set Depth Alarm
NO DECO
C Z
DECO
C Z
O
2