31
Time display. To get back to the surface, the diver must ascend to just
deeper than 40 feet staying as close to 40 feet as possible without
causing the DEC Time display to flash. The DEC digits may flash at
depths slightly deeper than 40 feet in some situations. If this happens,
descend to the shallowest depth below 40 feet where the flashing stops.
After waiting until the Tissue Loading Bar Graph recedes into the 30 foot
zone, the diver can then ascend to not less than 30 feet and continue decom-
pressing. After more time, the bar graph will recede into the 20 and then 10
foot zones after which the diver can ascend to not less than 20 or 10 feet
respectively. After DEC Time reaches zero and the Tissue Loading Bar
Graph recedes into the yellow Caution Zone (C.Z.), the diver can surface.
However, to add a greater margin of protection, Oceanic strongly recom-
mends that you wait until the segments are well within the green No Decom
zone, unless a low air condition requires you to surface. Five minutes after
reaching the surface, the Sport will enter Immediate Violation Mode and will
then revert to Gauge Mode (see page 33).
Delayed Violation #2 -
Spending More than 5 Minutes Above Decompression Ceiling
If you stay above the decompression ceiling for more than five minutes,
you will enter Delayed Violation Mode. At this time the TLBG will flash (Fig.
24). If you descend back beneath the ceiling after this five minute time
Summary of Contents for DataMax Sport
Page 1: ...DataMax Sport owner s guide model DRB...
Page 5: ...THE DATAMAX SPORT IS EASY TO USE...
Page 13: ...DETAILED OPERATIONS GUIDE...
Page 29: ...HANDLING THE EXTREMES...
Page 42: ...38 this page intentionally left blank...
Page 43: ...CARE and MAINTENANCE...
Page 53: ...REFERENCE...
Page 59: ...NOTES...