43
GEO 4.0 OPERATING MANUAL
© Pelagic, 2019
Doc. No. 12-5670-r01 (2/27/18)
HIGH O
2
SAT (OXYGEN SATURATION)
Warning >> at 80 to 99% (240 OTU)
Alarm >> at 100% (300 OTU)
Warning
When O
2
reaches the Warning Level, the audible alarm sounds and the O2 SAT (saturation) value will flash in place of the
DTR (Dive Time Remaining). The DTR will be restored when the audible alarm is silenced.
DURING AUDIBLE ALARM
AFTER AUDIBLE ALARM
flashing
DTR restored,
showing O2 min
Alarm
If O2 SAT reaches the Alarm level, the audible alarm sounds. At the same time, the up arrow and the O2 SAT value will
flash in place of DTR until surfacing.
flashing
flashing
Warning During Decompression
When O2 SAT reaches the Warning Level, the audible alarm sounds and the O2 SAT value will flash in place of Total
Ascent Time. The Total Ascent Time will be restored when the audible alarm is silenced.
DURING AUDIBLE ALARM
flashing
Alarm During Decompression
When O2 SAT reaches the Alarm Level, the audible alarm sounds and the O2 SAT value will flash in place of Total Ascent
Time until surfacing.
flashing
Summary of Contents for GEO 4.0
Page 6: ...6 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 GETTING STARTED...
Page 12: ...12 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 WATCH MODE...
Page 19: ...19 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 DIVE FEATURES...
Page 24: ...24 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 NORM SURFACE MODE...
Page 36: ...36 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 NORM DIVE MODE...
Page 45: ...45 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 GAUGE MODE...
Page 49: ...49 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 FREE MODE...
Page 55: ...55 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 REFERENCE...
Page 59: ...59 GEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5670 r01 2 27 18 TECHNICAL DATA...