v. If the button is not pressed for five minutes after it shuts down it will automatically go into it
drain cycle, it will take around 8 minutes for this to complete itself. The generator will take in
more water when it is draining to flush out the boiler, this action is designed to minimize the
build up of lime scale but not allow the elements to dry out while they are still hot. The process
will only occur after the generator has operated for more than 10 minutes or more
vi. To deactivate “steam on demand” hold drain for 5 seconds until L4 changes green.
11. Troubleshooting guide
Please note that we recommend all repairs are carried out be a suitably qualified person.
Trouble description
Cause
Something is wrong with:
Solution
When the generator is
turned on there is no
display on control panel.
Connection
Power supply
Transformer.
Main circuit board controller
Control cable or port
Connection
Fuse
1. Check you have power to the main terminals.
2. Check fuse.
3. Disconnect control cable from main circuit board,
spray multipurpose lubricant or electrical connection
cleaner on the pins and in the socket, blow away excess,
reconnect.
4. If there are no RED LEDs on the main circuit board the
transformer has failed or has a loose connection.
Control panel lit up but no
steam.
Water probe
Control lead connection
Water supply
1. If L2 is green, L7 is yellow remove the water level
probe, clean off any scale, return probe. Test
2. Disconnect control cable from main circuit board,
spray multipurpose lubricant or electrical connection
cleaner on the pins and in the socket, blow away excess,
reconnect.
3. If L2 is red, check water supply, if ok shut of water and
take inlet valve apart, clean filter and return. If still red
replace inlet valve.
Circuit breaker tripping
out.
Element failure
Loose Earth Wire
Faulty connection
1. To check elements use a insulation tester, or fault find
by disconnecting individual elements one by one.
2. Check earth connections are tight.
3. If above fails, return generator to supplier for repair,
guarantee information below.
Temperature window
displays “LC”
The temp sensor connection
1. Check connection or change temp sensor.
2. If above fails replace sensor.
Temperature window
display “HC”
Temp sensor is short circuit.
1. Check connection or change temp sensor.
2. If above fails replace sensor.
Water runs through steam
nozzle in room.
Water inlet valve.
Level sensor.
1. Turn machine off, if water continues clean inlet valve
or replace.
2. If runs while machine is on try above if fails clean
water probe and check connection to circuit board.
Generator works when
switched off on the control
panel.
Relays
1. Replace relay PCB.