background image

Installing the hood

43

Determine the location of the hood cabinet. This must

be installed at a maximum distance of 820 mm from
the box table.
To fix it to the wall, drill 4 holes by placing them so
that they correspond to the hole in the back of the
hood.Insert plugs corresponding to the type of
material of your wall in the holes.

Screw the two screws ST4x 30 mm from the top

and hang the hood.
Remove the two filtersthen attach the hood box to the
wall with 2 other ST4x 30mm screws. Place the check
valve on the hood.

Summary of Contents for OCEAHC202SS

Page 1: ...Hotte Visi re Guide d utilisation Visor Hood User manual OCEAHC202SS OCEAHC202SB OCEAHC202SW...

Page 2: ...taller et d utiliser le produit Table des mati res Trouver des informations 2 Instructions de s curit importantes 3 Lampe 9 Description du produit 10 Description des pi ces 11 Installation de la hotte...

Page 3: ...ment avant d installer ou d utiliser cet appareil Cet appareil a t con u pour tre utilis comme une hotte aspirante l vacuation de l air l ext rieur ou une hotte filtrante le recyclage de l air l int r...

Page 4: ...ctement surveill e s ou si des instructions relatives l utilisation de l appareil en toute s curit leur ont t donn es et si les risques encourus ont t appr hend s Les enfants ne doivent pas jouer avec...

Page 5: ...e pas utiliser d a rosols proximit imm diate de l appareil Veillez jeter le mat riel d emballage avec soin Nous vous recommandons galement de prendre une attention particuli re pendant l utilisation e...

Page 6: ...bation avec la ventilation de la pi ce lors de la pr sence d appareils fonctionnant au gaz chauffe eau gazini re En cas de doute utilisez la hotte en mode recyclage Une ventilation convenable de la pi...

Page 7: ...incendie nettoyez r guli rement le filtre m tallique et surveillez constamment les casseroles contenant de l huile chaude Ne pas flamber d aliments sous la hotte de cuisine Ne pas utiliser l appareil...

Page 8: ...E Il y des risques de choc lectrique et d incendie si le nettoyage n est pas effectu conform ment aux instructions MISE EN GARDE Pour raison de s curit utilisez seulement des vis de m me dimensions qu...

Page 9: ...s et les images de ces lampes Utilisation dans une lampe de type ou utilisation dans une lampe de type alternatif DBL 2 H 120 code ILCOS D respectant la norme IEC 61231 Lampe LED non rempla able Puiss...

Page 10: ...Description du produit 10 1 Caisson de la hotte 2 Sortie d vacuation Clapet anti retour...

Page 11: ...cription des pi ces 11 Index Description Illustration Quantit PL 1 Caisson de la hotte 1 PL 2 Sortie 1 d vacuation Clapet anti retour PL 3 Couvercle rond 1 PL 4 Vis ST4 30 mm 6 PL 5 Filtre plat carbon...

Page 12: ...le mettre en service Installation Mode extraction Si le mur comporte une ouverture donnant sur l ext rieur votre hotte peut tre raccord e comme indiqu sur le sch ma ci dessous au moyen de la gaine d...

Page 13: ...Veillez ce que le conduit soit le plus court et rectiligne possible Pour permettre une utilisation optimale le conduit ne doit pas d passer 2 50 m de long au total Le conduit doit donner directement...

Page 14: ...c pas recommand s Installation Mode recyclage Si vous n avez pas de sortie vers l ext rieur la gaine d extraction n est pas n cessaire et les proc dures d installation sont identiques celles d crites...

Page 15: ...me rebouch s Consultez imp rativement un professionnel du b timent pour utiliser le syst me d ancrage vis chevilles appropri au mat riau qui constitue votre mur ainsi qu au poids de l appareil Respec...

Page 16: ...nstallation assurez vous que l appareil n est pas branch sur une prise lectrique Les sch mas suivants indiquent les distances et l ordre des trous percer Les 2 vis de suspension du bloc principal doiv...

Page 17: ...mur percez 4 trous en les pla ant de fa on ce qu ils correspondent au per age l arri re de la hotte Ins rez des chevilles correspondant au type de mat riau de votre mur dans les trous Vissez les deux...

Page 18: ...te au placard l aide de 4 vis ST4x30mm Avertissement Ne pas suivre les instructions pour l installation des vis ou dispositifs de fixation peut entra ner des dangers lectriques ATTENTION En mode extra...

Page 19: ...En mode recyclage la grille d vacuation sur l avant de la hotte ne doit pas tre recouverte...

Page 20: ...iliser un outil pour retirer le couvercle rond avant de l utiliser l air pourra ainsi tre vacu vers le haut Ventilation horizontale Voir sch ma B et C Veuillez utiliser un outil pour retirer le couver...

Page 21: ...icale ou horizontale allumez la hotte l air est ainsi vacu vers l ext rieur du b timent vacuation int rieure mode recyclage Tournez l ajusteur sur la position int rieure les couvercles ronds et rectan...

Page 22: ...l ancien filtre plat en carbone et placez les nouveaux Remarque Le filtre plat charbon est install l arri re de la grille et doit tre chang tous les trois mois Attention Le filtre plat charbon ne peut...

Page 23: ...s chimiques de mat riaux abrasifs ou de brosses dures pour nettoyer l unit Nettoyage mensuel pour filtre graisse ESSENTIEL Nettoyer le filtre tous les mois peut pr venir tout risque d incendie Le filt...

Page 24: ...Appuyez sur ce bouton pour faire fonctionner le syst me faible vitesse Bouton Vitesse moyenne Appuyez sur ce bouton pour faire fonctionner le syst me vitesse moyenne Bouton Vitesse lev e Appuyez sur c...

Page 25: ...et le tableau lectrique Aucune lumi re Lampe hors service La lampe ne peut tre remplac e que par un professionnel Forte vibration de la hotte La turbine est coinc e Eteignez l appareil et faites inter...

Page 26: ...nt de rendement maximal QBEP 107 8 m3 h Pression d air mesur e au point de rendement maximal PBEP 174 Pa D bit d air maximal Qmax 201 9 m3 h D bit d air au point de travail r glage le plus lev 194 m3...

Page 27: ...gie mesur e en mode veille Ps W Consommation d lectricit mesur en mode arr t PO 0 00 W Niveau de puissance acoustique LWA R glage le plus haut 55 R glage le plus bas 46 dB La m thode de mesure et de c...

Page 28: ...Informations compl mentaires 27 OCEANIC 120 126 quai de Bacalan CS11584 33000 Bordeaux Import par A M C 123 quai JulesGuesde 94400 Vitrysur Seine...

Page 29: ...e de vie l appareil ne doit pas tre mis au rebut avec les d chets m nagers Pour des conseils sur le recyclage veuillez contacter votre administration locale ou votre revendeur D CHET RESPECTANT L ENVI...

Page 30: ...uide carefully before installing and using the product Contents Find some informations 29 Important safety instructions 30 Lamp 35 Product Description 36 Description of the pieces 37 Installing the ho...

Page 31: ...ughly prior to installation This appliance has been designed for use as an exhausting air evacuation to the outside or filtering indoor air re cycling hood All installation work must be carried out by...

Page 32: ...the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Regularly ch...

Page 33: ...rated by means of external timeror separated remote control system Warning When using for extraction refer to thenational regulations for building ventilation systems Do not connect the exhaust pipe t...

Page 34: ...off the electricity supply to the hood and reconnect after one minute To avoid the risk of fire clean the metal filter regularly and closely watch and regulate pans containing hot oil Flambe cooking...

Page 35: ...shock and fireif cleaning is not carried out in accordance with the instructions Warning For safety reason please use only thesame size of fixing or mounting screw which are recommended in this instr...

Page 36: ...rrespondence ILCOS D codes and lamp pictures Use type lamp or use in alternative type lamp DBL 2 H 120 ILCOS D code in according to standard IEC 61231 Non replaceable LED lamp Max wattage 2 W Voltage...

Page 37: ...Product Description 36 1 Hood casing 2 Exhaust outlet check valve...

Page 38: ...Description of the pieces 37 Index Description Illustration Quantity PL 1 Hood casing 1 PL 2 Exit outlet Anti 1 return flag valve PL 3 Round lid 1 PL 4 Screws ST4 30 6 mm PL 5 Flat carbon filter 2...

Page 39: ...he product before putting it into service Installation Mode extraction If the wall has an opening to the outside your hood may be connected as shown in the diagram below using the extraction duct prov...

Page 40: ...aust duct outward Make sure that the duct path is as short and straight as possible To allow optimal use the duct must not exceed 2 50m long in total The duct must lead directly to the outside and mus...

Page 41: ...re not recommended for using Installation Mode recycling If you do not have an exit to the outside the exhaust duct is not required and the installation procedures aresame as those described except th...

Page 42: ...lugged It is imperative that you consult a building professional to use the anchoring system screws dowels etc appropriate to the material that constitutes your wall as well as to the weight of the ap...

Page 43: ...installing make sure the unit is not plugged into an electrical outlet The following diagrams show the distances and holes to be drilled The 2 suspension screws of the main unit must be mounted at a m...

Page 44: ...wall drill 4 holes by placing them so that they correspond to the hole in the back of the hood Insert plugs corresponding to the type of material of your wall in the holes Screw the two screws ST4x 30...

Page 45: ...ve on the hood Secure the hood to the cabinet with 4 screws ST4x30 mm WARNING In extraction mode fastening underneath a cabinet requires the use of an exhaust duct extending to the top of the cabinet...

Page 46: ...ventilation See Pic A Please use tool take out the round cover before using and the air can be vented from top Horizontal ventilation See Pic B and C Please use a tool to remove the rectangular cover...

Page 47: ...tall the outlet turn on the cooker hood then the air will be vented from the outside outlet Internal evacuation mode recycling Turn the adjuster to inner position install the rould lid Turn on the hoo...

Page 48: ...aw out the old carbon flat filter and place the new ones Note The flat carbon filter is installed at the back of the rack and must be changed every three months Caution The flat carbon filter can not...

Page 49: ...e metal pads chemical abrasive material or stiff brush to clean the unit Monthly Cleaning for Grease Filter ESSENTIAL Clean the filter every month can prevent any risk of fire The filter collects grea...

Page 50: ...speed button Press this button to operate the system at low speed Middle speed button Press this button to operate the system at medium speed High speed button Press this button to operate the system...

Page 51: ...s Plug in to the power supply again Serious Vibration The fan blade is Switch of the unit and repair by of the unit jammed qualified service personnel only The fan motor is Switch of the unit and repa...

Page 52: ...ex EEIhotte 69 3 Measured air flow rate at best QBEP m3 h efficiency point 107 8 Measured air pressure at bestefficiency point PBEP 174 Pa Maximum airflow Qmax 201 9 m3 h Air flow at working point hig...

Page 53: ...h Commission Regulation EU No 65 2014 and 66 2014 Lighting efficiency class A Grease Filtering Efficiency GFEhotte 64 1 Grease Filtering Efficiency class E Measured power consumption in standby mode P...

Page 54: ...Further information 53 OCEANIC 120 126 quai de Bacalan CS11584 33000 Bordeaux Import par A M C 123 quai Jules Guesde 94400 Vitry sur Seine...

Page 55: ...user At the end of its life cycle the appliance must not be disposed of with household waste For recycling tips please contact your local administration or dealer ENVIRONMENTAL PROTECTION Electrical a...

Page 56: ...www oceanic eu...