Page 37 of 43
Setting of 7 pre-set 24-hour programs (P1-P7)
Under program mode setting interface, regardless of which day, when you choose program from
P1 to P7, press and hold OK for 3 seconds to enter the setting interface of the mode. The setting
will be memorized (in case of power failure, it will also be memorized).
1. Choose mode for the hour: press + to choose comfort mode
, – to choose economic mode
,
or OK to keep previous setting. After on, it will automatically go to setting for next hour.
2. At the last hour, press + / -, or OK to finish the setting and go back to previous setting
interface.
For example, if you enter the P1 setting from below interface (day 1, P1), it will go back to
below interface (day 1, P1) after you finish P1 24-hour setting.
Notes:
3. In case of power failure, the unit keep in memory only the parameters,
temperature and operating mode. When power is restored, the clock should be
adjusted again to operate the program modes properly.
4. After you finish program mode setting, it will be saved but will not automatically
start working at program mode. You need to press OK to choose program mode to
make the heater work at this mode.
1. Window detection mode
Press
+
&
-
at the same time to enter setting menu interface and choose window detector
function
by pressing
+ /
-. Press
OK
button to enter window detector function. Then press
+
Heure