OCi OPERATING MANUAL

© 2002 Design, 2013

Doc. No. 12-5335-r02 (9/12/13)

OCi

DIVE COMPUTER

OPERATING MANUAL

Summary of Contents for OCi

Page 1: ...1 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 OCi DIVE COMPUTER OPERATING MANUAL...

Page 2: ...2 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 Welcome to OCEANIC and Thank You for choosing the OCi...

Page 3: ...ities Menu NORM GAUG 24 Set Water Type 24 Set Wet Activation 24 Set Units 24 Set Deep Stop 24 Set Safety Stop 25 Set Algorithm 25 Set Conservative Factor 25 Set Backlight Duration 25 Set Sampling Rate...

Page 4: ...the Oceanic logo type OCi the OCi logo Air Time Remaining ATR Diver Replaceable Batteries Graphic Diver Interface Tissue Loading Bar Graph TLBG Pre Dive Planning Sequence PDPS Set Point Control Consol...

Page 5: ...5 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 FEATURES AND FUNCTIONS...

Page 6: ...ve Mode NW Northwest compass Nx Nitrox gas O2 Oxygen OP Operating mode OCi Watch Dive Computers are placed in a Deep Sleep mode prior to being shipped from the factory The intent is to extend storage...

Page 7: ...in Menu Set Compass Declination Menu Log History Menu Compass Reference Menu Gas TMT Switch Menu Each Menu has a Start First selection and a Stop Last selection Upon entering a Menu movement through i...

Page 8: ...t Declin if REF SURFACE 2 s 2 s NORM GAUG SET MENU STRUCTURE NORM GAUG Main Menu Set G Menu Gas 1 Gas 2 Gas 3 Gas 4 FO2 Default Set A Menu Aud AL Depth AL EDT AL TLBG AL DTR AL Turn AL End AL Set U Me...

Page 9: ...t will turn off when the Alarm is silenced The Audible and LED will not be active if the Audible is Set OFF a Set Alarms setting FREE Dive Modes have their own Alarms which emit multiple beeps multipl...

Page 10: ...ng level Backlight is completely disabled Battery icon shell with inner bar appears solid Fig 1Aa If a dive is started the icon is not displayed on the dive mode screens Watch and DC functions includi...

Page 11: ...11 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 WATCH MODE...

Page 12: ...Day or Day Month TLBG if any after NORM or FREE dives Alarm speaker icon if the Daily Alarm is set On Battery icon if a Low Battery condition A 2 sec to access ALT 2 Reverts to the Default Time scree...

Page 13: ...Minute digits A hold to scroll upward through the Minutes set points at 8 second from 00 to 59 in 1 minute 01 increments A 2 sec to step up through the set points one at a time M 2 sec to step back t...

Page 14: ...forward through the selections M 2 sec to step up back through the selections S 2 sec to access the menu selection indicated by the pointer icon Set Date Format information includes Fig 10 Date Forma...

Page 15: ...set Graphics ALT TIME solid with ON flashing and SET solid numeric Hour differential with graphic Hour solid A or M 2 sec to toggle between ON and SET S 2 sec to save the selection and revert to the m...

Page 16: ...16 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM SURFACE MODES...

Page 17: ...et for 5 seconds When Wet Activation is set Off dive mode will only activate when operating in a Dive Computer mode It will not activate while in Watch Mode unless it is a repetitive dive in a series...

Page 18: ...and MAX icons 2 dashes if no previous dive Elapsed Dive Time hr min with graphic EDT 3 dashes if no previous dive A 2 sec to access ALT 2 10 sec revert to Main if A is not pressed L to activate Backl...

Page 19: ...sed for planning Graphic AIR or numeric value 21 to 100 of FO2 set for Gas 1 PO2 Alarm value set for Gas 1 1 00 to 1 60 if Nitrox blank if Air Nx icon if Nitrox S 2 sec to access the first screen of t...

Page 20: ...des Fig 26 Pre dive Surface Interval hr min with SURF icon 0 00 if Dive 1 Max Depth with graphic FT or M MAX Elapsed Dive Time hr min with graphic EDT Graphic SEA or EL2 to EL7 altitude at which the d...

Page 21: ...next to SET GAS on the NORM Main Menu A 2 sec to step down forward through selections M 2 sec to step up back through selections S 2 sec to access the selection indicated by the pointer icon The last...

Page 22: ...the selections S 2 sec save the selection If OFF or ON is selected operation reverts to the Alarms Menu If SET is selected the Depth digits will flash A hold to scroll through set points 8 sec from 3...

Page 23: ...d M 2 sec or 2 min of no button action to revert to the Surface Main SET TURN TMT 1 PRESSURE ALARM information includes Fig 39 Graphics TURN ALARM Graphics OFF ON and SET last saved OFF or ON flashing...

Page 24: ...ain SET WET ACTIVATION information includes Fig 43 Graphics WET ACTIV Graphics OFF and ON last one saved flashing S 2 sec to revert to the Set Utilities Menu without changing the setting A or M 2 sec...

Page 25: ...for nitrogen and oxygen calculations Z is more conservative allowing shorter No Deco times at specific depths Refer to page 31 Changing the algorihm is blocked during 24 hours after NORM and FREE dive...

Page 26: ...ections OFF ON SET M 2 sec to step upward through the selections S 2 sec to save the selection If TMT 1 is set OFF the OCi s receiver will be disabled and operation will revert to the TMT Menu If ON i...

Page 27: ...set procedure S 2 sec to start the first 2 digits xx flashing A hold to scroll upward through the first digits xx 4 per sec A 2 sec to step upward through the digits xx one at a time M 2 sec to step b...

Page 28: ...28 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 DIVE MODE FEATURES...

Page 29: ...when it is held out to the sides of the TMT or held at distances greater than 4 feet 1 2 meters in front of the TMT Best reception is achieved when the OCi is within 3 feet 1 meter of the TMT When ins...

Page 30: ...emain On throughout the full dive until entry into Sur face mode at which time the Backlight operation will revert to normal controlled by the L button and Duration time set BAR GRAPHS The OCi feature...

Page 31: ...lated Stop Depth for 10 seconds during the countdown the No Deco Main will replace the Deep Stop screen and the Deep Stop feature will be disabled for the remainder of that dive There is no Penalty if...

Page 32: ...ou selected dur ing setup the End Pressure alarm setting Tank pressure is measured once each second and an average rate of consumption is calculated over a 90 second period and used in conjunction wit...

Page 33: ...33 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM DIVE MODE...

Page 34: ...e the Backlight On Off L 2 sec while the Backlight is On to reset the timer and keep it On for the duration time set NO DECO ALT 2 information includes Fig 73 Time of Day hr min_sec with A or P if 12...

Page 35: ...down to 0 00 Graphic GAS 1 or 2 3 4 the one currently in use NX icon if any Gas is set for Nitrox Air Time Remaining up to 99 min with min and ATR icons Tank Pressure for the TMT currently in use wit...

Page 36: ...epth with graphic FT or M Stop Time hr min Graphic GAS 1 or 2 3 4 the one currently in use NX icon if any Gas is set for Nitrox Air Time Remaining up to 99 min with min and ATR icons blank if no TMT i...

Page 37: ...for 10 seconds during which the full TLBG will flash Fig 86 until the Audible is silenced The Audible cannot be silenced by pressing S The graphic DOWN with Down Arrow icons continue to flash until w...

Page 38: ...nd Link icons or graphic SPG TLBG with icon flashing during the Audible then removed VARI with icon if ascending A 2 sec to access ALT 1 S 2 sec to access the Compass Operating Main L 2 sec to toggle...

Page 39: ...silence the Audible When the Audible is silenced DTR will be restored If O2 increases to the Alarm level 100 the Audible will sound again and the O2 value with graphic O2 SAT will replace DTR Fig 95...

Page 40: ...40 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 NORM GAS TMT SWITCHING...

Page 41: ...Fig 100B and the Switch will be canceled Gas Switch Alarm If a switch to the new Gas would result in PO2 1 60 the Audible will sound and a warning message will flash Fig 101 until the Audible is silen...

Page 42: ...42 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 DIGITAL GAUGE OP MODE...

Page 43: ...2s M 2s A 2s M S 2s FLY LOG SET A SET U OP MODE HISTORY OCi ID BATT TMT M 2s access selection ALTs DIVE at 5 FT 1 5 M for 5 sec at 2 FT 0 6 M for 1 sec Surface Mode Dive Mode Reset Run Timer S 2s Star...

Page 44: ...A or P Altitude graphic if EL2 to EL7 blank if Sea level Temperature with icon and graphic F or C A 2 sec to revert to Main 10 sec revert to Main if A is not pressed L to operate the Backlight GAUG MA...

Page 45: ...2 sec while the Backlight is On to reset the timer and keep it On for the duration time set GAUG DIVE ALT information includes Fig 109 Max Depth with FT or M and MAX icons Time of Day hr min_sec with...

Page 46: ...TMT 1 TMT 2 TMT 3 TMT 4 with OFF ON settings The Arrow icon next to the TMT in use A 2 sec to step forward down through the selections M 2 sec to step back up through the selections S 2 sec to access...

Page 47: ...47 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 FREE DIVE TECH FREE DIVE OP MODES...

Page 48: ...after SCUBA activities Allows unrestricted use of operating buttons during dives for control of the Backlight and Timers Features 3 Depth Alarms set for progressively deeper depths TECH FREE DIVE MODE...

Page 49: ...ng that data is from the dive previously conducted while in FREE or TECH FREE mode Max Depth with FT or M and MAX icons 2 dashes if no previous dive Elapsed Dive Time up to 9 59 min sec with graphic E...

Page 50: ...to scroll upward through Minute set points at a rate of 8 per second from 0 to 59 in increments of 1 min A 2 sec to step upward through set points one at a time M 2 sec to step back through set points...

Page 51: ...ax Depth with graphics FT or M and MAX Elapsed Dive Time up to 9 59 min sec with graphic EDT Graphic SEA or EL2 to EL7 the Altitude level at which the dive was conducted Temperature with icon and grap...

Page 52: ...ed that day and the Max Depth displayed is associated with that Dive Time Elapsed Dive Time min sec for that dive with graphic EDT Graphic DAY and Date Month Day or Day Month of the dive S 2 sec to ac...

Page 53: ...graphic EDT the average EDT of all dives ever recorded The average number of dives conducted each day up to 99 with the graphic divE S 2 sec to access the Full History Data 1 screen S 2 sec to exit a...

Page 54: ...to step back to the Set Alarms Menu S 2 sec to save the setting If OFF or ON is selected operation will revert to the Set Alarms Menu If SET is selected the Minute digits will flash S 2 sec to step b...

Page 55: ...ALARM information includes Fig 139A Depth with FT or M icon Graphics DEPTH ALARM 1 and DA1 Graphics OFF ON and SET last saved OFF or ON flashing upon access A 2 sec to step forward down through the se...

Page 56: ...FREE only fixed rate in FREE determines the interval at which data is sampled and recorded for upload to the PC Interface program It does not affect the rate at which data is measured for the display...

Page 57: ...the Set Utilities Menu If SET is selected the Depth digits will flash S 2 sec to step back to SET flashing A 2 sec to step upward through the set points of 2 4 6 FT 0 6 1 2 1 8 M one at a time M 2 se...

Page 58: ...with Elapsed Dive Time up to 9 59 min sec Graphic NDC with No Deco Time Remaining hr min Temperature with icon and graphic F or C TLBG with icon if any nitrogen loading from FREE or NORM dives conduct...

Page 59: ...Main repeating after another time interval DIVE RDI REPEATING DEPTH INTERVAL ALARM Fig 153 Each time Depth reaches the Interval set the Audible will sound 3 sets of 3 500 second beeps during which th...

Page 60: ...ccount the physiological changes associated with the high pressures that competitive type Free diving can expose a diver to WARNINGS Ensure that you know which Operating Mode is selected NORM GAUG FRE...

Page 61: ...61 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 COMPASS MODE...

Page 62: ...k to OP Main rotate level SET DECLIN OFF EAST WEST S 2s S 2s save back to Compass Menu S 2s Set 0 to 45 S 2s Battery Change DATA A 2s toggle S 2s DATA SAVED CAL COMPASS L S 2s S 2s SAVE CLEAR or CLEAR...

Page 63: ...f travel Dynamic moving Arrow relative direction of magnetic North Tilt icon when the Compass is at an angle 20 off level Numeric heading diver s current direction 001 to 360 with position graphic N E...

Page 64: ...Numeric heading diver s direction at lower right with position graphic On time remaining counting down if 15 to 0 sec S 2 sec to step back to the Reference Menu S 2 sec to reverse and save the new Re...

Page 65: ...tion Menu A hold to scroll upward through set points at a rate of 4 sec from 0 to 45 in increments of 1 A 2 sec to increase set points one at a time M 2 sec to step back through set points one at a ti...

Page 66: ...TION When the procedure provided in this section is used to change the Battery you must be sure that the case o ring is not pinched and that the OCi is water tight before conducting diving activities...

Page 67: ...be installed on the PC or Mac and open the associated USB Driver is to be installed and the interface cable is to be plugged into the PC or Mac USB Port then connected to the OCi s Data Port When a wa...

Page 68: ...ollow must be closely adhered to avoid entrance of water into the unit Damage due to improper Battery replacement or subsequent leakage of moisture into the unit is not covered by the OCi s 2 year war...

Page 69: ...with selections SAVE and CLEAR will be displayed Fig 185 giving you the option to retain or delete Ni O2 calculations for repetitive dives A 2 sec to toggle between SAVE and CLEAR S 2 sec to save the...

Page 70: ...70 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 TECHNICAL DATA...

Page 71: ...0 03 54 0 05 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 57 0 05 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 DSAT ALGORITHM NDLS HR MIN AT ALTITUDE IMPERIAL Altitude 0 3001 4001...

Page 72: ...ve made yet Resets to Dive 1 upon diving after 24 hours with no dives Dive Log Mode Stores 24 most recent NORM GAUG dives in memory for viewing After 24 dives adds 25th dive in memory and deletes the...

Page 73: ...co Safety Stop Time 5 00 to 0 00 min sec 1 second Deco Stop Time 0 00 to 9 59 hr min 1 minute Total Ascent Time 0 00 to 9 59 hr min 1 minute Violation Countdown Timer 23 50 to 0 00 hr min 1 minute GAU...

Page 74: ..._____________________________________________________ Date of Purchase ___________________________________________________________________________________________________ Purchased from ______________...

Page 75: ...www oceanic eu com E mail office oceanic de OCEANIC UK Devon United Kingdom Tel 44 1404 891819 Fax 44 0 1404 891909 Web www OceanicUK com E mail helpyou oceanicuk com OCEANIC AUSTRALIA Rosebud Victori...

Page 76: ...76 OCi OPERATING MANUAL 2002 Design 2013 Doc No 12 5335 r02 9 12 13 OCi DIVE COMPUTER OPERATING MANUAL...