DV 1 (DELAYED VIOLATION 1)

If you remain shallower than a Deco Stop Depth for more than 5 minutes, operation will enter DV1* which is a continuation of 

CV with penalty time still being added.  The audible will sound and the full TLBG will flash (Fig. 66) until it is silent.

*The difference is that 5 minutes after surfacing from the dive, operation will now enter Violation Gauge Mode. 

•  S (press) to activate the Backlight.

>  Down Arrow icon continues to flash until descent to below required Stop Depth, then full Stop icon will be on solid. 

DV 2 (DELAYED VIOLATION 2)

If the calculated Deco obligation requires a Stop Depth between 60 FT (18 M) and 70 FT (21 M), operation will enter DV2. 

The Audible will sound and the alarm LED will flash.  The full TLBG will flash until the audible is silent. 

•  S (press) to activate the Backlight.

>  Up Arrow icon flashes if 10 FT (3 M) deeper than the required Stop Depth.  

>  Once within 10 FT (3 M) of and below the required Stop Depth, the Stop icon (both Arrows with Stop Bar) will be displayed 

solid (Fig. 67).

DV 3 (DELAYED VIOLATION 3)

If you descend deeper than the MOD*, the audible will sound and the alarm LED will flash.  Also, the graphic UP and Up Arrow 

icon will flash (Fig. 68), and Current Depth, DTR (NDC), and Max Depth will only display dashes ( - - ) signifying that you are Too 

Deep.  

*MOD is the Max Operating Depth at which the Pro Plus 3 can properly perform calculations or provide accurate display 

information. Refer to the Specifications in the back.

Upon ascending above the MOD, Current Depth will be restored, however, Max Depth will continue to be displayed as dashes 

for the remainder of that dive.  The Log for that dive will also display dashes for Max Depth.  

VGM (VIOLATION GAUGE MODE)

Operation will enter VGM when Deco requires a Stop Depth greater than 70 FT (21 M). 

Operation would then continue in VGM during the remainder of that dive and for 24 hours after surfacing.  VGM turns the Pro 

Plus 3 into a digital instrument without any decompression or oxygen related calculations or displays. 

Upon activation of VGM, the Audible will sound and the alarm LED will flash.  

VGM Dive Main, 

information includes (Fig. 69) -

>  Current Depth with FT (or M) icon.

>  Graphics UP VIOL (in place of Max Depth which moves to Alt 1) with Up Arrow icon, flashing until on surface

>  EDT with DIVE and min icons

>  NX, Gas icons - if they apply 

>  VARI while ascending

•  A (< 2 sec) to access ALTs (similar to those for Deco).

•  A (2 sec) to access Gas Switch routine, unless Gas 2 is set Off.

•  S (press) to activate Backlight.

VGM on Surface

Upon surfacing, the VGM Dive Main will remain on display for 10 minutes with Surface Interval Time 

displayed in place of Current Depth with the SURF icon flashing.  The graphic VIO will also still be dis-

played flashing (Fig. 70).  

Operation will also enter VGM 5 minutes after surfacing from a dive in which a Delayed Violation 

occurred. 

After 10 minutes elapse, VIO alternates with NOR until the unit shuts off after 24 hours with no dives.

>  A full 24 hour continuous surface interval must then be served before all functions are restored.

>  During that 24 hours, VGM does not allow access to the Set Gas or Plan, or provide Time to Dsat.  

>  The Fly countdown indicates time remaining before normal operation can resume with full features 

and functions.

Fig. 70  - VGM SURF MAIN

Fig. 67 - DV2 MAIN

(at the stop)

Fig. 66  - DV1 MAIN

(during Audible)

Fig. 68 - DV 3 MAIN

(during Audible)

Fig. 69  - VGM DIVE MAIN

(during Audible)

TLBG

VARI

Summary of Contents for PRO PLUS 3

Page 1: ...1 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 PRO PLUS 3 DIVE COMPUTER OPERATING MANUAL...

Page 2: ...GLO 17 Set Sampling Rate SR 17 SET TIME 17 Set Date Format 18 Set Hour Format 18 Set Time 18 Set Date 18 SET OPERATING MODE 18 HISTORY MODE 19 SERIAL NUMBER 19 DIVE MODE FEATURES 20 BAR GRAPHS 21 TLB...

Page 3: ...All rights are reserved PATENT NOTICE U S Patents have been issued or applied for to protect the following design features Data Sensing and Processing Device U S Patent No 4 882 678 Air Time Remainin...

Page 4: ...4 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 Welcome to OCEANIC and THANK YOU for choosing the PRO PLUS 3...

Page 5: ...5 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 FEATURES and FUNCTIONS...

Page 6: ...rough menu selections A hold to scroll forward through menu selections S 2 sec to access or save selections A 2 sec while viewing the last selection in the menu will revert to the first selection such...

Page 7: ...M is exceeded in NORM mode or 400 FT 120 M in GAUG mode A single short beep which cannot be disabled sounds when After 10 minutes on the surface after the Violation dive 3 short beeps which cannot be...

Page 8: ...t dive LOW BATTERY WHILE ON THE SURFACE 2 75 volts warning level DC functions continue Backlight is disabled Battery icon appears solid Fig 1a 2 50 volts Too Low alarm level All operations cease Batte...

Page 9: ...9 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 NORM SURFACE MODES...

Page 10: ...if FO2 for any gas is set for Nitrox Gas tank 1 icon default on surface Dive number with icon up to 24 for that operating period 0 if no dive made yet Graphic NOR operating mode Tank 1 Pressure with P...

Page 11: ...Dive times are reduced to the values of the next higher 3000 foot 915 meter Altitude Refer to tables in back Plan Lead in information includes Fig 8A B Max Depth allowed for the PO2 alarm value set f...

Page 12: ...to access Data 1 for the dive Preview displayed S 2 sec to revert to the Lead in screen S press to activate SMARTGLO Backlight Log Data 1 information includes Fig 12 Log book icon Pre dive SI hr min...

Page 13: ...ation includes Fig 16 17 Max Depth allowed for the PO2 alarm set with MAX and FT or M icons blank if Air NX Z or DSAT CF icons those that apply Gas 1 icon PO2 alarm value set ATA for Gas 1 with icon b...

Page 14: ...e selected saved S 2 sec to step back to Set Audible Alarm Set EDT Alarm information includes Fig 22 Graphic OFF or ON flashing Time with EDT and min icons last value saved A 2 sec to step through sel...

Page 15: ...Turn Pressure Alarm information includes Fig 25 Graphic turn Graphic OFF or ON flashing Tank Pressure with PSI or BAR icon last value saved A 2 sec to step through selections OFF ON and Set one at a...

Page 16: ...Fig 30 Graphics dEEP STOP with Stop arrow bar and DS icons Graphic OFF or ON flashing A 2 sec to toggle between OFF and ON S 2 sec to save the setting and access Set SS S 2 sec to step back to Set Un...

Page 17: ...the selections OFF ON Set S 2 sec to save the setting S 2 sec to step back to Set CF If OFF or ON is selected operation will access Set SR If Set is selected Duration Time seconds will flash in place...

Page 18: ...d through Minute set points one at a time S 2 sec to save the Time set point and access Set Date S 2 sec to revert to Set Hour Format Set Date information includes Fig 40 The sequence for setting date...

Page 19: ...cludes Fig 44 HIST icon with graphic EVER Max Depth ever recorded with MAX and FT or M icons Longest Elapsed Dive Time ever recorded during a single dive up to 599 min with EDT and min icons S 2 sec t...

Page 20: ...20 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 DIVE MODE FEATURES...

Page 21: ...Deco dives considered more risky Z Pelagic Z performance is based on Buhlmann ZHL 16c It features NDLs that are considerably more conservative especially at shallower depths To create even greater mar...

Page 22: ...displayed as DTR Fig 48a It will also be displayed graphically as the TLBG Fig 48b As you ascend the TLBG segments will recede as control shifts to slower compartments This is a feature of the decompr...

Page 23: ...23 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 NORM DIVE MODES...

Page 24: ...cklight NO DECO ALT 2 information includes Fig 54 Time of Day hr min with AM or PM icon if 12 Hour Format no icon if 24 Hour Format Temperature with F or C A 2 sec to access ALT 2 if Nitrox Revert to...

Page 25: ...r BAR icon graphic SPG Submersible Pressure Gauge if Gas 2 or 3 is in use TLBG A 2 sec to access ALT 1 A 2 sec to access Gas Switch routine unless Gas 2 is set Off S 2 sec to acknowledge alarms S pres...

Page 26: ...tion includes Fig 64 Max Depth with MAX and FT or M icons NX DSAT or Z Gas 1 2 3 CF icons those that apply Air Time Remaining with ATR icon 2 dashes if Gas 2 or 3 is in use Total Ascent Time with TAT...

Page 27: ...l continue to be displayed as dashes for the remainder of that dive The Log for that dive will also display dashes for Max Depth VGM VIOLATION GAUGE MODE Operation will enter VGM when Deco requires a...

Page 28: ...p the PO2 value 1 60 with icon will alternate with Deco Stop Depth Time once each minute No indication will be given suggesting ascent which is the diver s option pending conditions of the dive PO2 on...

Page 29: ...29 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 DIGITAL GAUGE MODE...

Page 30: ...e described previously for NORM Mode Button operations are also similar to those in NORM A 2 sec step forward through Menu items A hold scroll forward through Menu items S press activate the SMARTGLO...

Page 31: ...31 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 REFERENCE...

Page 32: ...r better microprocessor Microsoft Windows XP Vista or 7 Super VGA card or compatible video graphics adaptor 256 color or greater with a minimum 800 X 600 pixel screen area of display settings 16MB of...

Page 33: ...ating entrance of moisture into the unit If corrosion is found return the Pro Plus 3 to an Authorized Oceanic Dealer and DO NOT attempt to use it until it has re ceived factory service Moisture in the...

Page 34: ...me that the Wet Contacts are bridged When diving in high altitude waters from 3 001 to 14 000 feet 916 to 4 270 meters the Pro Plus 3 automatically adjusts to these conditions providing corrected Dept...

Page 35: ...3 12 11 11 10 9 9 9 8 30 16 12 11 10 9 9 9 8 8 7 7 7 33 13 9 9 8 8 7 7 7 7 6 6 6 36 10 8 7 7 7 6 6 6 5 5 5 5 39 9 7 6 6 6 6 5 5 5 5 5 4 42 8 6 6 5 5 5 5 5 4 4 4 4 45 6 5 5 5 5 4 4 4 4 4 4 4 48 6 5 5 4...

Page 36: ...evel beginning at 3 001 feet 916 meters elevation and every 1 000 feet 305 meters higher Power 1 3 volt type CR2 Lithium battery Shelf life Up to 5 years dependent on battery manufacturer Replacement...

Page 37: ...itrox Value 21 to 100 1 PO2 Value 0 00 to 1 99 ATA 01 ATA 1 when 2 00 O2 Saturation 0 to 100 1 Pressure 0 to 5000 PSI 345 BAR 5 PSI 1 BAR Elapsed Dive Time 0 to 599 min 1 minute Dive Time Remaining 0...

Page 38: ...orized Oceanic Dealer Date Service Performed Dealer Technician OCEANIC WORLD WIDE OCEANIC USA 2002 Davis Street San Leandro CA 94577 Tel 510 562 0500 Fax 510 569 5404 Web www OceanicWorldwide com E ma...

Page 39: ...39 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 NOTES...

Page 40: ...40 PRO PLUS 3 OPERATING MANUAL 2002 Design 2012 Doc No 12 5332 r01 11 19 12 PRO PLUS 3 DIVE COMPUTER OPERATING MANUAL...

Reviews: