19
PROPLUS X OPERATING MANUAL
© Pelagic, 2016
Doc. No. 12-5655-r01 (8/19/16)
DTR (DIVE TIME REMAINING)
The ProPlus X constantly monitors No Decompression status and O2 Accumulation, and will display whichever time is the least amount available as
DTR on the No Decompression Dive Main screen. The time being displayed will be identified by the NDC (no decompression) or OTR (Oxygen Time
Remaining) icons.
NO DECOMPRESSION
No Decompression is the maximum amount of time that you can stay at your present depth before entering decompression. It is calculated based on
the amount of nitrogen absorbed by hypothetical tissue compartments. The rates each of these compartments absorb and release nitrogen is math-
ematically modeled and compared against a maximum allowable nitrogen level.
Whichever compartment is closest to this maximum level is the controlling compartment for that depth. Its resulting value NDC (no decompression)
will be displayed. It will also be displayed graphically as the Tissue Loading Bar Graph, see Bar Graphs later in this section.
As you ascend, the Tissue Loading Bar Graph will recede as control shifts to slower compartments. This is a feature of the decompression model that
is the basis for multilevel diving, one of the most important advantages that Aqua Lung dive computers offer.
AR
%
11
DS
GAS 1
32%
FO2 PO2
1.20
16
125
FT
NDC
NORM
74°
F
12:36
PM
70%
54
TL
%
2340
PSI
D1B
(v) TO MENU - (>) TO COMPASS
47
EDT
21
GTR
OTR (OXYGEN TIME REMAINING)
When set for nitrox operation, O2 SAT (Oxygen Saturation) during a dive is displayed on the More Dive Data screen as a percentage of allowed
saturation identified by O2 SAT. The limit for O2 SAT (100%) is set at 300 OTU (Oxygen Tolerance Units) per dive or 24 hour period. See the chart
at the back of this manual for specific times and allowances. O2 SAT and OTR (Oxygen Time Remaining) values are inversely related; as the O2
SAT value increases the OTR (Oxygen Time Remaining) value decreases.
When the OTR (Oxygen Time Remaining) value becomes less than the No Decompression calculations for the dive, DTR (Dive Time Remaining) will
be controlled by O2 SAT and the OTR (Oxygen time Remaining) value will be displayed as the DTR on the Dive Main screen, identified by the OTR
icon.
DTR is
No Decompression
NORM
MORE DIVE DATA
NDC
DIVE TIME
MAX DEPTH
TIME OF DAY
GAS 1 FO2
TEMPERATURE
GAS 1 PO2 AL
CURRENT PO2
O2 SAT
= 13
min
= 37
min
= 132
FT
= 11:46
AM
= 74°
F
= 32
%
= 1.40
= 24
%
= 0.84
(<) BACK TO MENU
O2 Sat during
a nitrox dive
BAR GRAPHS
The ProPlus X features two specific bar graphs.
1. The one on the left represents nitrogen loading. It is referred to as TL (Tissue Loading) Bar Graph.
2. The one on the right represents ascent rate. It is referred to as the AR (Ascent Rate) Bar Graph.
AR
%
11
DS
GAS 1
32%
FO2 PO2
1.20
16
125
FT
NDC
NORM
74°
F
12:36
PM
70%
54
TL
%
2340
PSI
D1B
(v) TO MENU - (>) TO COMPASS
47
EDT
21
GTR
Tissue Loading
Bar Graph
Ascent Rate
Bar Graph
Summary of Contents for PROPLUS X
Page 5: ...5 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GETTING STARTED...
Page 10: ...10 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 HOME MENU...
Page 18: ...18 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 DIVE FEATURES...
Page 23: ...23 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM SURFACE MODE...
Page 34: ...34 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM DIVE MODE...
Page 44: ...44 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GAUGE MODE...
Page 47: ...47 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 COMPASS MODE...
Page 51: ...51 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 REFERENCE...
Page 54: ...54 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 TECHNICAL DATA...