41
PROPLUS X OPERATING MANUAL
© Pelagic, 2016
Doc. No. 12-5655-r01 (8/19/16)
AR
%
0
-
GAS 1
AIR
FO2 PO2
-
- -
TL
%
(v) TO MENU - (>) TO COMPASS
GO UP
VIOLATION
136
FT
1067
PSI
18
GTR
VIOLATION GAUGE MODE (VGM) DURING A DIVE
During Dive mode dives, operation will enter VGM when Decompression requires a Stop Depth greater than 70 ft (21 m). Operation would then
continue in VGM during the remainder of that dive and for 24 hours after surfacing. VGM turns the ProPlus X into a digital instrument without any
decompression or oxygen related calculations or displays. Upon activation of VGM, the audible alarm will sound. The message VIOLATION GO UP
with up arrows will flash. After the audible alarm becomes silent (10 seconds), the NDC (No Decompression) and Tissue Loading Bar Graph will not
display for the rest of the dive.
GAS 1
-
AIR
FO2 PO2
-
:
0 04
VIOLATION
SURF
TL
- -
%
1067
PSI
(v) TO MENU - (>) TO COMPASS
5
DIVE
--
GTR
VIOLATION GAUGE MODE (VGM) ON THE SURFACE
The message VIOLATION is displayed until 24 hours elapse with no dives. During that 24 hours, VGM lockout does not allow access to the Set Gas,
Plan, and Desat features/screens. The Compass function will be allowed.
• The Fly countdown timer provides the time remaining before normal operation can resume with full features and functions.
• In the event that a dive is made during the 24 hour lockout period, a full 24 hour surface interval must then be served before all functions are
restored.
AR
%
11
GAS 1
32%
FO2
PO2
1.20
124
FT
54
TL
%
1024
PSI
(v) TO MENU - (>) TO COMPASS
19
GTR
WARNING
PO2 = 1.20
HIGH PO
2
Warning >> at Alarm Set Point value minus .20
Alarm >> at Set Point value, except in Deco then at ≥1.60 only
WARNING
When PO
2
(partial pressure of oxygen) increases to the Warning level; the audible alarm sounds and the PO
2
value will flash in place of
NDC (No Decompression) and EDT (Elapsed Dive Time) until the audible alarm is silenced.
Summary of Contents for PROPLUS X
Page 5: ...5 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GETTING STARTED...
Page 10: ...10 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 HOME MENU...
Page 18: ...18 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 DIVE FEATURES...
Page 23: ...23 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM SURFACE MODE...
Page 34: ...34 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM DIVE MODE...
Page 44: ...44 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GAUGE MODE...
Page 47: ...47 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 COMPASS MODE...
Page 51: ...51 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 REFERENCE...
Page 54: ...54 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 TECHNICAL DATA...