42
PROPLUS X OPERATING MANUAL
© Pelagic, 2016
Doc. No. 12-5655-r01 (8/19/16)
ALARM
If PO
2
continues to increase and reaches the alarm set point, the audible alarm sounds again. The PO
2
value, GO UP message, and up
arrows will flash during the audible alarm. After the audible alarm is silenced, they alternate with NDC (No Decompression) and EDT
(Elapsed Dive Time) until PO
2
decreases below the alarm set point.
AR
%
0
GAS 1
32%
FO2
PO2
1.40
128
FT
54
TL
%
1003
PSI
(v) TO MENU - (>) TO COMPASS
19
GTR
ALARM
PO2 = 1.40
GO UP
PO
2
DURING DECOMPRESSION
The PO
2
alarm setting does not apply when in Decompression. If PO
2
exceeds 1.60 while in Decompression, the PO
2
value (= 1.60) will
flash during the audible alarm. After the audible alarm is silenced, they alternate with Deco Stop/Time until PO
2
decreases below 1.60.
AR
%
0
GAS 1
32%
FO2
PO2
1.60
132
FT
100
TL
%
1299
PSI
(v) TO MENU - (>) TO COMPASS
11
GTR
ALARM
PO2 = 1.60
AR
%
20
GAS 1
32%
FO2 PO2
1.20
75
FT
54
TL
%
1024
PSI
(v) TO MENU - (>) TO COMPASS
19
GTR
WARNING
02SAT = 80%
HIGH O
2
SAT (OXYGEN SATURATION)
Warning >> at 80 to 99% (240 OTU)
Alarm >> at 100% (300 OTU)
WARNING
When O
2
reaches the Warning Level, the audible alarm sounds and the O2 SAT (oxygen saturation) value will flash in place of NDC (No
Decompression) and EDT (Elapsed Dive Time). They will be restored when the audible alarm is silenced.
AR
%
0
GAS 1
32%
FO2 PO2
1.40
75
FT
54
TL
%
1003
PSI
(v) TO MENU - (>) TO COMPASS
19
GTR
O2 = 100%
ALARM
GO UP
ALARM
If O2 SAT reaches the Alarm level, the audible alarm sounds. The GO UP message, up arrows, and the O2 SAT value will flash in place of
NDC (No Decompression) and EDT (Elapsed Dive Time). They will be solid after the audible alarm is silenced.
Summary of Contents for PROPLUS X
Page 5: ...5 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GETTING STARTED...
Page 10: ...10 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 HOME MENU...
Page 18: ...18 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 DIVE FEATURES...
Page 23: ...23 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM SURFACE MODE...
Page 34: ...34 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM DIVE MODE...
Page 44: ...44 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GAUGE MODE...
Page 47: ...47 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 COMPASS MODE...
Page 51: ...51 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 REFERENCE...
Page 54: ...54 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 TECHNICAL DATA...