57
PROPLUS X OPERATING MANUAL
© Pelagic, 2016
Doc. No. 12-5655-r01 (8/19/16)
CAN BE USED AS
• Dive Computer (Air or Nitrox)
• Digital Depth Gauge/Timer
DIVE COMPUTER PERFORMANCE
• Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm.
• No Decompression limits closely follow PADI RDP.
• Decompression in agreement with Buhlmann ZHL-16c and French MN90.
• No Decompression Deep Stops - Morroni, Bennett.
• Decompression Deep Stops (not recommended) - Blatteau, Gerth, Gutvik.
• Altitude - Buhlmann, IANTD, RDP (Cross).
• Altitude corrections and O2 limits based on NOAA tables.
OPERATIONAL PERFORMANCE
Function:
Accuracy:
• Depth
±1% of full scale
• Timers
1 second per day
Dive Mode Activation:
• Manually by pressing any button or automatic by immersion in water.
• Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters)
Dive Counter:
• Norm/Gauge displays Dives #1 to 24.
• Resets to Dive #1, upon diving (after 24 hours with no dives).
Dive Log Mode:
• Stores max 24 entries per day, 99 entries in memory for viewing.
• After 24 dives in one day or 99 dives overall, new dives overwrite older dives.
Altitude:
• Operational from sea level to 14,000 feet (4,270 meters) elevation.
• Measures ambient pressure every 30 minutes in Watch mode, when Dive Computer mode is accessed, and every 15 minutes while in DC Surface
modes.
• Does not measure ambient pressure when wet.
• Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power:
• Rechargeable lithium battery
• Replacement: factory only
Battery Indicator:
• Graphical level gauge
Operating Temperature:
• Out of the water - between 20 °F and 140 °F (-6 and 60 °C).
• In the water - between 28 °F and 95 °F (-2 and 35 °C).
BAR GRAPHS:
TLBG
• No Deco Normal zone 0-70%
• No Deco Caution zone 71-99%
• Decompression zone 100%
VARI
• Normal zone
0-70%
• Caution zone
71-99%
• Too Fast zone
100%
SPECIFICATIONS
Summary of Contents for PROPLUS X
Page 5: ...5 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GETTING STARTED...
Page 10: ...10 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 HOME MENU...
Page 18: ...18 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 DIVE FEATURES...
Page 23: ...23 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM SURFACE MODE...
Page 34: ...34 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 NORM DIVE MODE...
Page 44: ...44 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 GAUGE MODE...
Page 47: ...47 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 COMPASS MODE...
Page 51: ...51 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 REFERENCE...
Page 54: ...54 PROPLUS X OPERATING MANUAL Pelagic 2016 Doc No 12 5655 r01 8 19 16 TECHNICAL DATA...