12
POWER SUPPLY
The Veo 100 utilizes 1 - 3 volt CR2450 Lithium Battery which
should provide from 100 dive hours of operation, if you conduct
1 - one hour dive each time the unit is activated, to as many as
300 dive hours of operation, if you conduct 3 or more one dives
each time the unit is activated.
Low Battery Condition
• Voltage level is checked upon activation and every 10
minutes during operation.
• When 75 % of the Rated Power has been consumed, a
Battery icon will appear on the Surface Mode display (Fig.
6a) flashing once per second as a warning that the Battery is
to be replaced prior to conducting any further dives.
• Upon decreasing to a voltage level that will no longer sustain
proper operation, the icon will flash 5 times followed by
shutdown of the unit.
• If a Low Battery Condition exists when the unit is manually
activated (by pressing the button), the icon will appear
flashing for 5 seconds followed by shutdown of the unit.
• If the button is not pressed to activate the unit prior to a dive
(e.g., the unit activated automatically by immersion in water),
and a Low Battery Condition exists, the Battery icon will
appear flashing as a warning upon descent to 5 feet (1.5
meters). No other information will be displayed and the unit
will not enter Dive Mode.
Fig. 6 - Low Battery
(surface mode)
a