32
The added Penalty (decompression) Time will then have to be
worked off first, before obtaining off-gassing Credit.
Once the Penalty Time is worked-off, and off-gassing Credit
begins, required decompression Stop Depths and Time will
decrease toward zero, then the Tissue Loading Bar Graph will
recede into the yellow Caution Zone and operation will revert to
the No Decompression Dive Mode.
Delayed Violation Mode #1
(Fig. 30)
If you remain above the Required Ceiling Stop Depth
for 'more than 5 minutes',
the Tissue Loading Bar Graph
and Total Ascent Time display will flash until you descend below
the Required Stop Depth. This is a continuation of a Conditional
Violation.
Delayed Violation Mode #2
(Fig. 31)
The Veo 100 cannot calculate decompression times for Stop
Depths much greater than 60 FT (18 M) and offers no indication
of how much time spent underwater would result in the need for a
greater Stop Depth.
If your Decompression obligation requires a Ceiling
Stop Depth 'between' 60 feet (18 meters) and 70 feet
(21 meters),
the Tissue Loading Bar Graph will flash. Total
Ascent Time will still be displayed.
Fig. 30 - Delay Viola #1
Fig. 31 - Delay Viola #2