37
Log Data will not be stored in the unit's memory until the 10
minute Transition Period on the surface is completed.
Once 10 minutes have elapsed, the Surface Mode icon and
Surface Interval time display colon stop flashing indicating that
the Dive and Transition Period are completed, and a subsequent
Descent will be considered a new dive.
If you Descend during the 10 minute Transition Period, time
underwater will be considered a continuation of that dive. Time
spent at the surface will not be added as Dive Time.
AFTER THE TRANSITION PERIOD (THE FIRST 2 HOURS)
For the remainder of the
first 2 hours after surfacing
,
information will continue to be displayed as the Surface Se-
quence, scrolling through Surface Mode > Time to Fly > Time to
Desaturate > Pre Dive Planning Sequence. You will have full
access to Log Mode and Set Mode.
Time to Fly/Desaturate
The Time to Fly and Desat Timers begin counting down 10
minutes after surfacing from a dive (after the Transition Period).
The FLY countdown (Fig. 37) always begins at 23:50 (hr:min)
and the Desat countdown (Fig. 38) at 23:50 (maximum).
Fig. 37 - Time to Fly
Fig. 38 - Time to Desaturate