47
Deeper than 60 FT (18 M)
VARI
Ascent Rate
Segments
FPM
MPM
0
0 - 20
0 - 6
1
21 - 30
6.1 - 9
2
31 - 40
9.1 - 12
3
41 - 50
12.1 - 15
4
51 - 60
15.1 - 18
5
60 +
18 +
60 FT (18 M) & Shallower
VARI
Ascent Rate
Segments
FPM
MPM
0
0 - 10
0 - 3
1
11 - 15
3.1 - 4.5
2
16 - 20
4.6 - 6
3
21 - 25
6.1 - 7.5
4
26 - 30
7.6 - 9
5
30 +
9 +
Fig. 48 - DIVE MAIN
(Ascent normal)
Fig. 49 - DIVE MAIN
(Ascent Too Fast)
a
VARI (NORM and GAUG)
The VARI (Fig. 48a) provides a visual representation of ascent
speed (i.e., an ascent speedometer).
The segments represent two sets of speeds which change at a
reference depth of 60 FT (18 M). Refer to the chart.
When ascent is too fast, all segments will be displayed flashing
(Fig. 49) until ascent is slowed.
WARNING: When deeper than 60 FT (18 M), as-
cent rates should not exceed 60 FPM (18 MPM).
At depths of 60 FT (18 M) and shallower, ascent
rates should not exceed 30 FPM (9 MPM).