59
HIGH PO2 DIVE MODE
When partial pressure of oxygen (PO2) becomes equal to, or
greater than, 1.40 ATA, or 0.2 ATA less than the PO2
Alarm set point (a user setting); the red LED warning will
flash, the Audible Alarm will sound (unless set OFF), and the
current PO2 value, PO2 symbol, O2 segment of the O2 Bar
Graph, and UP Arrow will appear on the Main Display as a
warning until PO2 decreases. Current Depth and Dive Time
Remaining will also be displayed (Fig. 61).
If PO2 continues to increase, the value displayed will increase
toward a maximum value of 5.00 ATA in increments of .01
ATA. When it reaches a value of 1.60 ATA, or the PO2
Alarm set point (a user setting), the Audible Alarm will
sound (unless set OFF) and the current PO2 value, PO2 symbol,
O2 segment of the O2 Bar Graph, and UP Arrow will flash as a
warning until PO2 decreases (Fig. 62).
Press the Left/Front (Advance) button to view the Alternate
Displays.
The unit will revert to the Main Display after 3 seconds.
Press the Right/Side (Select) button to activate the Backlight.
Fig. 61 - PO2 Warning
Fig. 62 - PO2 Alarm