35
Set Depth Alarm,
information includes (Fig. 21):
> Graphics SEt and - dA
> Graphic OFF or Depth value flashing with MAX and FT (or
M) icons
• A (hold) to scroll upward through Set Points at a rate of 8
per second from 30 to 330 FT (10 to 100 M) in increments
of 10 FT (1 M).
• A (< 2 sec) to step upward through Set Points one at a time.
• M (< 2 sec) to step back through Set Points one at a time.
• S (< 2 sec) to save the setting and access Set EDT Alarm.
• S (2 sec) to revert to Set Audible Alarm.
Set EDT Alarm,
information includes (Fig. 22):
> Graphics SEt and EDT -
> Time value flashing with DIVE and min icons
• A (hold) to scroll upward through Set Points at a rate
of 8 per second from OFF to 10 through 180 (min) in
increments of 5 min.
• A (< 2 sec) to step upward through Set Points one at a time.
• M (< 2 sec) to step back through Set Points one at a time.
• S (< 2 sec) to save the setting and access Set TLBG Alarm.
• S (2 sec) to revert to Set Depth Alarm.
Fig. 21 - SET DEPTH AL
Fig. 22 - SET EDT AL
Summary of Contents for VEO 3.0
Page 1: ......
Page 2: ......
Page 9: ...9 Welcome to OCEANIC and THANK YOU for choosing the VEO 3 0 FEATURES AND FUNCTIONS...
Page 19: ...19 NORM SURFACE MENU MODES...
Page 49: ...49 DIVE MODE FEATURES...
Page 57: ...57 NORM DIVE MODES...
Page 73: ...73 DIGITAL GAUGE MODE...
Page 79: ...79 FREE DIVE MODE...
Page 91: ...91 REFERENCE...
Page 103: ...103 TECHNICAL DATA...
Page 111: ...111...
Page 112: ......