VEO 4.0 OPERATING MANUAL

© Pelagic, 2019

Doc. No. 12-5671-r01 (3/20/19)

ADV

SEL

9. SAMPLING RATE

The Sample Rate controls how frequently the Veo 4.0 stores a data snapshot for Di Download during a dive. Set-

ting options are 2, 15, 30, or 60 second intervals. Shorter intervals will provide a more precise record of your dives.

  NOTE: New data will automatically overwrite the oldest data in memory when the memory becomes 

full. The Veo 4.0 Log and Di Download data are stored separately in different partitions of the 
memory. The Log only stores a short summary of each dive. Alternately, the Di Download function 

stores much larger files for each dive. Depending on the chosen settings and dive durations, it is possible 

to see dives stored in the Veo 4.0's onboard Log that have already been overwritten in the Di 

Download Partition. Choosing a longer Sample Rate interval will consume less memory per dive. Remem-
ber to download your dives more frequently if you are using a shorter Sample Rate interval. 

DIVE & GAUGE 

DOWNLOAD MEMORY

CAPACITY

SAMPLE 

RATE 

(seconds)

MAXIMUM 

HOURS

2

4

15

32

30

64

60

128

increase

value

ADV

SEL

to select

2, 15, 30, or 60 sec

SET T (TIME)

Pressing the SEL button while viewing the Set TIME Lead-in screen accesses the Set TIME Sub Menu. Within this menu you can set the time formats, 

date, and time of day. 

next item 

in Main 

Menu

access

Set T

Menu

SET TIME LEAD-IN

ADV

SEL

toggle 

setting

to select

SET DATE FORMAT

(M - D) or

(D - M)

M = month

D = day

ADV

SEL

toggle 

setting

to select

SET HOUR FORMAT

12 or 24

ADV

SEL

advance 

setpoint

to select

SET TIME

ADV

SEL

advance

setpoint

to select

SET DATE

Choose and save 

the hours. Then 

repeat for minutes.

blank if 

value is

A.M.

or D - M depending 

on selected format

Choose and save the 

year. Then repeat for 

the month and day.

Summary of Contents for VEO 4.0

Page 1: ...1 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 VEO 4 0 DIVE COMPUTER OPERATING MANUAL...

Page 2: ...TIME 27 SET MODE OPERATION MODE 28 HISTORY 28 SN SERIAL NUMBER 29 DIVE OPERATION 30 INITIATING A DIVE 31 NO DECOMPRESSION DIVE MAIN 31 GAS MENU 31 DIVE ALT 1 31 DIVE ALT 2 31 DEEP STOP PREVIEW 32 DEEP...

Page 3: ...NG MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 REFERENCE 51 UPLOADING DOWNLOADING DATA 52 CARE AND CLEANING 52 INSPECTIONS AND SERVICE 52 BATTERY REPLACEMENT 52 ALTITUDE SENSING AND ADJUSTMENT 54 T...

Page 4: ...Loading Bar Graph TLBG Pre Dive Planning Sequence PDPS OceanLog and Dual Algorithm are all registered and unregistered trademarks trade names and service marks of Pelagic All rights are reserved PATEN...

Page 5: ...5 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 Welcome to OCEANIC and THANK YOU for choosing the Veo 4 0...

Page 6: ...6 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 GETTING STARTED...

Page 7: ...is your preference Disabling the Wet Activation feature is described in the Dive Surface Mode chapter p 16 Upon activation The unit will enter a Diagnostic Mode The VEO 4 0 checks the display and volt...

Page 8: ...O DEC 10 Time To Surface 11 Oxygen Sat Saturation or min 12 Minutes 13 Bluetooth is on 14 Minutes 15 Low Battery 16 Fraction of Oxygen 17 Dive Time min or 18 Partial Pressure of Oxygen 19 Descend Asce...

Page 9: ...o used to enter settings activate the backlight and acknowledge the audible alarm Throughout this manual they will be referred to as the ADV and SEL buttons Pressing different combinations of these bu...

Page 10: ...r change setpoints to activate the backlight ADV SEL to scroll quickly changing setpoints to scroll quickly through menu lead in screens selections ADV SEL to select access step forward through select...

Page 11: ...11 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 DIVE FEATURES...

Page 12: ...e as control shifts to slower compartments This is a feature of the decompression model that is the basis for multilevel diving one of the most important advantages that Oceanic dive computers offer D...

Page 13: ...s based on Buhlmann ZHL 16c It features NDLs that are considerably more conservative than the DSAT version especially at shallower depths To create even greater margins of safety with respect to decom...

Page 14: ...the SS or choose to ignore it If set for Timer On Upon ascending to 20 FT 6 M for 1 second on a No Deco dive in which Depth exceeded 30 FT 9 M for 1 second 1 beep will sound and a Run Timer will appe...

Page 15: ...setting Free Dive Modes have their own alarms which emit multiple beeps multiple times which cannot be acknowledged or set to OFF Events that emit 10 beeps each sound for sec with sec silence between...

Page 16: ...16 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 DIVE SURFACE MODE...

Page 17: ...Main screen You may hold the ADV button to scroll quickly through the selections Some screens simply display data While other screens are lead ins to sub menus and settings Press the SEL button to cho...

Page 18: ...y then 9 59 to 0 00 hr min When the DESAT countdown reaches 0 00 hr min which will generally occur prior to the FLY countdown reaching 0 00 hr min it will remain on the display as 0 00 until the Fly c...

Page 19: ...of each dive Alternately the Diverlog Download function stores much larger files for each dive For this reason it is normal to see dives stored in the Veo 4 0 s onboard Log that have already been ove...

Page 20: ...2 or 3 gases Ad ditionally the Veo 4 0 allows for each gas to have individual PO2 alarm settings Within the Set Gas PO2 Alarm 1 2 and 3 screens the the current PO2 Alarm setting and corresponding MOD...

Page 21: ...can customize the following five alarm settings ADV SEL SET A LEAD IN next item in Main Menu to Set Audible Alarm 1 AUDIBLE ALARM The Audible Alarm feature allows you to set audible alarms ON or OFF A...

Page 22: ...FF 10 180 min 4 TLBG TISSUE LOADING BAR GRAPH ALARM This feature allows you to set an alarm to go off at a predetermined number of TLBG segments increase segments to select TLBG AL TRIGGERED flashing...

Page 23: ...he Wet Activation feature allows you to turn OFF water contact activation WARNING With Wet Activation turned OFF you must remember to manually activate the Dive Mode be fore any dive ADV SEL to select...

Page 24: ...ON is selected you may choose from an available 3 or 5 min Safety Stop at depths of 10 15 or 20 ft 3 4 5 or 6 m If TMR timer is selected a manual timer will be available instead of the automatic Safet...

Page 25: ...trogen and oxygen calculations See p 13 for further Dual Algorithm details NOTE Changing the algorithm is blocked during 24 hours after Dive Mode dives unless Desat time de creases to 0 00 ADV SEL tog...

Page 26: ...r mobile device using Diverlog software NOTE When Bluetooth is ON the Bluetooth icon will be displayed when on the surface with the screen activated Bluetooth is temporarily deactivated when the Veo 4...

Page 27: ...been overwritten in the Diverlog Download Partition Choosing a longer Sample Rate interval will consume less memory per dive Remem ber to download your dives more frequently if you are using a shorte...

Page 28: ...s a full function dive com puter in Dive or Free Mode HISTORY History is a summary of all basic data recorded during Dive and Gauge mode dives NOTE Dives made in Free mode are not shown in History or...

Page 29: ...rogen and oxygen calculations This is intended for facilities using the Veo 4 0 for rental or training activities not for general use by individual divers The feature is hidden to prevent accidental u...

Page 30: ...30 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 DIVE OPERATION...

Page 31: ...ventful dive in terms of safety Alarms are described in the Complications section of this chapter NOTE Before diving with the Veo 4 0 take time to familiarize yourself with both normal and alarm condi...

Page 32: ...ess up to 3 ALT displays by pressing the ADV button to cycle through them They are similar to the No Decompression Main Dive ALT 1 and Dive ALT 2 displays respectively See Deep Stop in the Dive Featur...

Page 33: ...en which is to reappear upon ascent again to 20 ft 6 m for 1 second In the event that the diver ascends above 10 ft 3 m for 10 seconds or enters Deco or a High O2 alarm condition occurs 100 while the...

Page 34: ...e current gas without switching The diver may override the Veo 4 0 and force the gas switch by pressing the SELECT button during the dont CHNG TO message WARNING Switching to gases with a PO2 above 1...

Page 35: ...ed on the max ascent rate allowed Time To Surface 0 999 then if greater than 999 min stop depth remaining stop time min up arrow DECOMPRESSION STOP MAIN Decompression deco Stop Main will display upon...

Page 36: ...min down arrow flashing Tissue Loading Bar Graph flashing missed stop depth DV1 5 MIN ON SURFACE Surface Time hour min DELAYED VIOLATION 2 DV 2 If the calculated Decompression obligation requires a St...

Page 37: ...hours VGM lockout does not allow access to the Set Gas Plan Desat and Free mode features screens All Watch functions will be allowed The Fly countdown timer provides the time remaining before normal o...

Page 38: ...ed showing O2 min Alarm If O2 SAT reaches the Alarm level the audible alarm sounds At the same time the up arrow and the O2 SAT value will flash in place of DTR until surfacing flashing flashing Warni...

Page 39: ...Decompression O2 SAT 100 will flash until the O2 SAT value decreases below 100 If you surface due to 100 O2 without having completed the Decompression obligation the full TLBG and O2 value 100 will fl...

Page 40: ...40 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 GAUGE MODE...

Page 41: ...o sub menus and settings Press the SEL button to choose menus or options from the Main Menu when available NOTE The Gauge Surface Main ALT screens and Menu options are similar to those described previ...

Page 42: ...r from the Main display hold the Alt button for 2 seconds The Timer will cancel upon surfacing NOTE Once the Run Timer is added and started it can be removed and continue to run in the background unti...

Page 43: ...um functional depth 330 ft 100 m is the depth at which the Veo 4 0 can properly perform calculations or provide accurate display information Upon ascending above the maximum functional depth current d...

Page 44: ...44 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 FREE MODE...

Page 45: ...associated with the high pressures that competitive type free diving can expose a diver to WARNINGS Ensure that you know which operating mode is selected Dive Gauge or Free prior to commencing any di...

Page 46: ...Surface Time min sec up to 59 59 then hr min dive up to 99 0 for none yet elapsed dive time min sec FREE SURF MAIN no dive yet or 1 min post dive residual nitrogen mode bluetooth on ALT 1 This screen...

Page 47: ...tting the CDT does not start the countdown You must select ON in the CDT Status screen to start the CDT flashing CDT ALARM TRIGGERED on surface during audible alarm SET FA FREE ALARMS Within this subm...

Page 48: ...Alarm 1 is set for 30 ft then Depth Alarm 2 settings start at 40 ft NOTE DA 2 and DA 3 are set the same way as DA 1 Press select to save settings and to return to the Main menu from Set DA 3 screen D...

Page 49: ...basic information including depth no decompression time dive time temperature and nitrogen loading during the dive No Decompression Time Remaining 0 599 min all times greater than 599 display as 599 T...

Page 50: ...issue Loading Bar Graph segments the audible alarm will sound again At this time the Tissue Loading Bar Graph segments will flash and NDC no decompression time will be displayed as 0 min When the audi...

Page 51: ...51 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 REFERENCE...

Page 52: ...terms of the 2 year limited warranty To Obtain Service Take your Veo 4 0 to an Authorized Oceanic Dealer or send it to the nearest Oceanic Regional Facility To return your Veo 4 0 to Oceanic Record a...

Page 53: ...corrosion is found return your Veo 4 0 to an authorized Oceanic dealer and DO NOT attempt to use it until it has received factory prescribed service Remove the cover O ring Discard and do not attempt...

Page 54: ...ngs must be within 1 foot 30 cm of each other to record that ambient pressure as the current Altitude No adjustments are made during any time that the Wet Contacts are bridged When diving in high alti...

Page 55: ...55 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 TECHNICAL DATA...

Page 56: ...05 0 05 0 05 0 05 150 0 08 0 06 0 06 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 160 0 07 0 06 0 05 0 05 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 170 0 07 0 05 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 04...

Page 57: ...03 0 03 0 03 0 03 180 0 05 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 190 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 03 0 00 Z BASED NDLS HR MIN METRIC Altitude 0 916 1221 1526 18...

Page 58: ...a level to 14 000 feet 4 270 meters elevation Measures ambient pressure every 30 minutes in Watch mode when Dive Computer mode is accessed and every 15 minutes while in DC Surface modes Does not measu...

Page 59: ...e 0 to 999 min 1 minute Dive Gauge Elapsed Dive Time 0 to 999 min 1 minute Free Elapsed Dive Time 10 min 0 00 to 9 59 min sec 1 second Free Elapsed Dive Time 10 min 10 to 999 min 1 minute Surface Inte...

Page 60: ...on altitude FO2 Fraction of Oxygen FORM Format date time FPM Feet Per Minute FT Feet depth HR Hour M Meters depth MAX Maximum M D D M Month Day Day Month MIN min Minutes time MPM Meters Per Minute NDC...

Page 61: ...e ___________________________________________________________________________________________________ Purchased from ___________________________________________________________________________________...

Page 62: ...62 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 Veo 4 0 DIVE COMPUTER OPERATING MANUAL...

Reviews: