VEO 4.0 OPERATING MANUAL
© Pelagic, 2019
Doc. No. 12-5671-r01 (3/20/19)
UPLOADING/DOWNLOADING DATA
As previously described (p. 26), the Veo 4.0 can be paired using the Bluetooth® feature. This requires a mobile device with Bluetooth® running
D software.
The Settings Upload portion of the program can be used to set/change the Gases, Set A (Alarms), Set U (Utilities), and Set T (Time/Date) using the
same Interface System. The Mode settings must be entered using the Veo 4.0 button controls.
Information available for retrieval* (download) from the Veo 4.0 includes items such as dive number, surface interval time, depth, dive time, start
dates/time, lowest temperature, sampling rate, set points, TLBG Bar Graph, and VARI Bar Graph.
*FREE Dive information is only available using the Di application.
Refer to the D software application for further instruction on linking your Veo 4.0 to your mobile device.
CARE AND CLEANING
Protect your Veo 4.0 from shock, excessive temperatures, exposure to chemicals, and tampering. Protect the lens against scratches with an Instru-
ment Lens Protector. Small scratches will naturally disappear underwater.
• Soak and rinse the Veo 4.0 in fresh water at the end of each day of diving, and check to ensure that the areas around the Low Pressure (Depth)
Sensor, wet contacts, and buttons are free of debris or obstructions.
• To dissolve salt crystals, use lukewarm water or a slightly acidic bath (50% white vinegar/50% fresh water). After removal from the bath, place
the Veo 4.0 under gently running fresh water. Towel dry before storing.
• Keep your Veo 4.0 cool, dry, and protected during transport.
INSPECTIONS AND SERVICE
Your Veo 4.0 should be inspected annually by an Authorized Oceanic Dealer who will perform a factory prescribed function check and inspection
for damage or wear. To keep the 2 year limited warranty in effect, this inspection must be completed one year after purchase (+/- 30 days). Oce
-
anic recommends that you continue to have an inspection performed every year to ensure it is working properly. The costs of annual inspections, or
inspections relating to water tight integrity, are not covered under the terms of the 2 year limited warranty.
To Obtain Service:
Take your Veo 4.0 to an Authorized Oceanic Dealer or send it to the nearest Oceanic Regional Facility.
To return your Veo 4.0 to Oceanic:
• Record all dive data in the Log and/or download the data stored in memory. All data will be erased during factory service.
• Package it using a protective cushioning material.
• Include a legible note stating the specific reason for return, your name, address, daytime phone number, serial number(s), and a copy of your
original sales receipt and Warranty Registration Card.
• Send freight prepaid and insured using a traceable method to the nearest Oceanic Regional Facility, or to Oceanic USA.
• If shipping to Oceanic USA, obtain an RA (Return Authorization) number by contacting Oceanic at 888-270-8595 or followthe instructions at
https://www.oceanicworldwide.com/us/support/returns/.
• Non-warranty service must be prepaid. COD is not accepted.
• Additional information is available at the Oceanic web site OceanicWorldwide.com
BATTERY REPLACEMENT
CAUTION: The procedures that follow must be closely adhered to avoid entrance of water into the unit. Damage due to improper
battery replacement (or subsequent leakage of moisture into the unit) is not covered by the Veo 4.0's warranty.
The battery compartment should be opened only in a dry and clean environment with extreme care taken to prevent the entrance of moisture or
dust.
As an additional precautionary measure to prevent formation of moisture in the battery compartment, it is recommended that the battery be
changed in an environment equivalent to the local outdoor temperature and humidity (e.g., do not change the battery in an air conditioned environ-
ment then take it outside during a hot sunny day).
Inspect the buttons, lens, and housing to ensure they are not cracked or damaged. If there is any sign of moisture in the Veo 4.0, DO NOT attempt
to use it for diving until it receives proper service by the Oceanic factory or an authorized regional distributor.
Data Retention
When the battery is removed, settings and nitrogen/oxygen calculations for repetitive dives will be retained in volatile memory until a new battery is
installed.
All parts needed for the battery change are provided in the Veo 4.0 Battery Kit available from your Oceanic Dealer.
low pressure
sensor
wet contacts
wet contact
Summary of Contents for VEO 4.0
Page 6: ...6 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 GETTING STARTED...
Page 11: ...11 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 DIVE FEATURES...
Page 16: ...16 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 DIVE SURFACE MODE...
Page 30: ...30 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 DIVE OPERATION...
Page 40: ...40 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 GAUGE MODE...
Page 44: ...44 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 FREE MODE...
Page 51: ...51 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 REFERENCE...
Page 55: ...55 VEO 4 0 OPERATING MANUAL Pelagic 2019 Doc No 12 5671 r01 3 20 19 TECHNICAL DATA...