VT 4.0 OPERATING MANUAL

© 2002 Design, 2011

Doc. No. 12-5213-r02 (9/6/11)

FLY/DESAT

 

FLY Time is a count down timer that begins counting down 10 minutes after surfacing from a dive from 23:50 to 0:00 (hr:min).

DESAT Time, also a count down timer, provides calculated time for tissue desaturation at sea level taking into consideration the 

Algorithm used and the Conservation Factor setting.  

DESAT Time also begins counting down 10 minutes after surfacing from a dive, counting down from 23:50 (max) to 0:00 

(hr:min). 

When the DESAT time reaches 0:00, which will generally occur prior to the FLY count down reaching 0:00, it will remain on the 

display until the FLY count down reaches 0:00.

 

>  DESAT is not displayed after a Gauge or Violation dive.

>  Desaturation requiring Times greater than 24 hours will display 23: - - .  

>  In the event that Time to Desaturate still remains at the end of 24 hours, the added time will be zeroed.

>  When other screens are accessed, the FLY and DESAT countdowns continue in the background.  

Fly/Desat,

 information includes (Fig. 10):

>  Graphics FLY and DSAT with countdown times (hr:min) and Time (clock) icon, dashes if no dive yet.

•  S (< 2 sec) to revert to Main Menu.

NORM PLAN MODE 

No Deco time Limits (NDLs) and O2 time Limits (OTLs) in Plan Mode are based on the Algorithm selected (DSAT or PZ+), the FO2 

set for Gas 1, and residual nitrogen (or O2) remaining from previous NORM (or FREE) dives.  FO2 set for other Gases are not 

used for Plan calculations. 

PDPS (Pre Dive Planning Sequence)

Plan screens will sequence through Depths from 30 to 190 FT (9 to 57 M), or the Max Depth that will allow theoretical No Deco 

Dive Time of at least 1 minute based upon the previous dive profiles in a series of repetitive dives and taking into account descent 

and ascent rates of 60 FPM (18 MPM).

When the Conservative Factor is set On, NDLs are reduced to the values of the next 3,000 foot (915 meter) higher Altitude.  

Refer to tables in back.  

PDPS,

 information includes (Fig. 11A/B):

>  Plan Depth value with FT (or M) icon.

>  Nx and (PZ+) icons, if they apply.

>  Max Depth allowed with FT (or M) and MAX, if Nx.

>  Graphic NDC (or OTL) with Dive Time allowed (min). 

>  Graphic GAS 1 with FO2 icon.

>  Graphic AIR; or PO2 alarm value set with icon and FO2 Nitrox value set, if Nx. 

•  A (hold) to scroll forward through screens at a rate of 4 per second increasing planned Depth from 30 to 190 FT (9 to 57 

M) in increments of 10 FT (3 M).

•  A (< 2 sec) to step forward through screens.

•  M (< 2 sec) to step back through screens.

•  S (< 2 sec) to exit and revert to the Main Menu.

NORM/GAUG LOG MODE

 

Information from the latest 24 NORM and/or GAUG dives is stored for viewing.  After exceeding 24 dives, the most recent dive 

is stored while the oldest is deleted. 

>  Dives are numbered from 1 to 24 starting each time NORM (or GAUG) Dive Mode is activated.  After 24 hours elapse with 

no dive, the first dive of the next period of operation is #1.

>  10 minutes after a dive, the Log screens for all dives stored can be viewed.

If a dive’s elapsed time (EDT) exceeds 599 (min), data at the 599 interval is recorded in the Log upon surfacing of the unit.

Main Menu >> Log Menu >> Dive >> Data 1 >> Data 2 >> Data 3.

Log Menu,

 information includes (Fig. 12):

>  Graphics LOG and MENU with mode (book) icon.

>  Listing* of dives displaying - - Number (1 to 24), Date, and start Time; or graphics NO DIVES YET if a new unit.

*Up and Down arrows are not displayed at the right due to space limitations.

•  A (hold) to scroll forward (down) through the listing at a rate of 8 entries per second.

•  A (< 2 sec) to step forward (down) through the listing.

•  M (< 2 sec) to step back (up) through the listing.

•  S (< 2 sec) to access that dive's Log Data 1 screen.

•  S (2 sec) to revert to Main Menu.

Fig. 10 - FLY/DESAT

Fig. 11A - PDPS

(Gas 1 set for Air)

Fig. 11B - PDPS

(Gas 1 set for Nitrox)

Fig. 11C - PDPS

(times controlled by O2)

NORM.MAIN

MENU

SELECT

>

FLY/DESAT

PLAN

LOG

SET.MENU

OP.MODE

HISTORY

VT.4.0.ID

BATT/TMT

DIVE.PREVIEW

Press S (< 2 sec) to 

access Log Menu.

Fig. 12 - LOG MENU

Summary of Contents for VT 4.0

Page 1: ...1 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 VT 4 0 DIVE COMPUTER OPERATING MANUAL...

Page 2: ...SAFETY STOP 22 DIVE TIME REMAINING DTR 22 No Deco DTR NDC 22 O2 DTR OTR 22 AIR TIME REMAINING ATR 23 NORM Dive Mode Structure 23 NORM DIVE MODES 24 NO DECO MAIN AND ALTS 25 DEEP STOP DS 26 SAFETY STOP...

Page 3: ...Dive Computer with Free Dive Mode and or Wireless Data Transmission U S Patent no 7 797 124 Air Time Remaining U S Patent no 4 586 136 and 6 543 444 and Data Sensing and Processing Device U S Patent...

Page 4: ...4 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 FEATURES FUNCTIONS...

Page 5: ...ithm type DTR Dive Time Remaining DURA Duration backlight E East compass EDT Elapsed Dive Time EL Elevation altitude FO2 Fraction of Oxygen FORM Format date time FREE Free Dive Mode FT Feet depth GAUG...

Page 6: ...to display alpha numeric messages and measured values as well as Menu type systems for selection of settings and various auxiliary functions It also serves as the Digital Compass which can be accesse...

Page 7: ...rt beeps which cannot be disabled sound when Ascent Rate is 51 to 60 FPM 15 1 to 18 MPM when deeper than 60 FT 18 M or 26 to 30 FPM 7 5 to 9 MPM at 60 FT 18 M and shallower FREE Dive Elapsed Dive Time...

Page 8: ...ttery icon shell only will flash for 5 seconds then the unit shuts off completely VT 4 0 LOW BATTERY DURING A DIVE 2 75 volts warning level Backlight is completely disabled All other functions continu...

Page 9: ...able until a Transition time elapses The reason for this is that making a descent during the first 10 minutes after surfacing from a NORM or GAUG dive or the first 1 minute after surfacing from a FREE...

Page 10: ...10 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 NORM SURFACE MODES...

Page 11: ...2 sec to activate Backlight NORM SURF ALT 2 information includes Fig 8 Altitude graphic if EL2 to EL7 blank if Sea level Time of Day hr min with graphic A or P Temperature with icon and graphic F or C...

Page 12: ...es of the next 3 000 foot 915 meter higher Altitude Refer to tables in back PDPS information includes Fig 11A B Plan Depth value with FT or M icon Nx and PZ icons if they apply Max Depth allowed with...

Page 13: ...when dive ended FO2 value set for Gas in used when dive ended with icon S 2 sec to revert to Log Menu S 2 sec at any time to revert to Log Menu NORM GAUG SET MENU The Set Menu selection provides acce...

Page 14: ...ed in the unit Graphic LCD with 01 or higher indicating the Display s revision number This number will change if Firmware is updated by factory service or by future download of revised firmware from t...

Page 15: ...2 Gas 1 is set for Nitrox 21 to 100 10 minutes on the surface after that dive the FO2 Gas 1 will be displayed as 50 and further dives will be calculated based on 50 O2 for oxygen calculations and 21 O...

Page 16: ...O DUR with Set Point 5 10 or 15 SEC time backlight remains on SAMPLE with Set Point 2 15 30 or 60 SEC rate data is recorded for PC download TO SET TMT MENU to access Set TMT menu These items apply to...

Page 17: ...flash the 2nd digit Repeat A M S button action until all digits are set with operation then reverting to the Set TMT Menu with SET solid SET T Time Date Menu information includes Graphics SEt t and ME...

Page 18: ...te A 2 sec to step forward down through selections M 2 sec to step back up through selections S 2 sec when the pointer icon is next a selection will save it as the Dive Main and revert to the Set Menu...

Page 19: ...19 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 DIVE MODE FEATURES...

Page 20: ...front of the TMT Best reception is achieved when the VT 4 0 is within less than 4 feet 1 2 meter of the TMT When installed into the high pressure ports of the Regulator First Stages the TMTs must be...

Page 21: ...sly and the TLBG displays the one that is in control of your dive at any given time VARI The VARI Fig 38b provides a visual representation of ascent speed i e an ascent speedometer The segments repres...

Page 22: ...it will be disabed for the remainder of that dive There is no Penalty if you surface prior to completing the SS or ignore it If set for Timer On Upon ascending to 20 FT 6 M for 1 second on a No Deco d...

Page 23: ...that you selected during setup End Pressure Alarm Setting ATR is displayed on the Dive Main screens Fig 42a ATR Alarm When ATR decreases to 5 minutes the Audible will sound and the ATR time digits an...

Page 24: ...24 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 NORM DIVE MODES...

Page 25: ...ccess Gas TMT Switching S 2 sec to activate Smartglo Backlight or acknowledge alarms S 2 sec to access Compass These items can only be accessed while viewing the Main No Deco Alt 1 information include...

Page 26: ...g 44 2 is similar to No Deco ALT 1 Fig 45 3 is similar to No Deco ALT 2 Fig 46 4 is similar to No Deco ALT 3 Fig 47 SAFETY STOP MAIN information includes Fig 50A B Current Depth with FT or M icon Nx P...

Page 27: ...N information includes Fig 52 Current Depth with FT or M icon Nx PZ CF icons if they apply Graphic DECO STOP with Stop icon arrows and bar Stop Depth with graphic FT or M and Stop Time up to 599 min w...

Page 28: ...TLBG will flash Two Up Arrows will also flash until within 10 FT 3 M of and below the required Stop Depth of 60 FT 18 M Once within 10 FT 3 M of and below the required Stop Depth the full Stop icon sm...

Page 29: ...vides the time remaining of the 24 hours required before normal operation can resume with full features and functions HIGH PO2 Warning at Alarm Set Point value minus 0 20 1 00 to 1 40 Alarm at Set Poi...

Page 30: ...end When O2 reaches 100 the Audible will sound again during which the O2 value 100 and 2 Up Arrows will flash until on the surface Fig 68 The full TLBG remains on solid as a reminder of Deco A 2 sec t...

Page 31: ...31 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 GAS TMT SWITCHING...

Page 32: ...d ATR will increase to maximum after 1 minute without a change in transmitted Pressure Gas Switch Alarm If a switch to the Gas would result in PO2 1 60 the Audible will sound and a warning message wil...

Page 33: ...LY LOG SET MENU OP MODE HISTORY VT 4 0 ID BATT TMT PREVIEW M 2 sec access selection ALTs GAUG DIVE S 2 sec DIVE MAIN M S A 2 sec 2 sec 2 sec 2 sec TMT Switch Compass Op Main Backlight Smartglo 60 sec...

Page 34: ...34 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 GAUG OP MODE...

Page 35: ...r P Temperature with icon and graphic F or C A 2 sec to access ALT 3 5 sec revert to Main if A is not pressed S 2 sec to activate Backlight GAUG SURF ALT 3 information includes Fig 83 Graphics GAUG an...

Page 36: ...can then be accessed directly by pressing M 2 sec while viewing the Surface Main A 2 sec to step forward down through selections M 2 sec to step back up through selections S 2 sec when the pointer ic...

Page 37: ...selections M 2 sec to step back through Menu selections S 2 sec when the pointer icon is next a selection will toggle it between solid and flashing Once 4 items are flashing another item cannot be to...

Page 38: ...th with MAX and FT or M icons if Run Timer is on Main Time of Day hr min with graphic A or P if 12 Hour Temperature with icon and graphic F or C A 2 sec to revert to Main Revert to Main in 5 sec if A...

Page 39: ...39 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 FREE DIVE OP MODE...

Page 40: ...ace Main CD TIMER Countdown Timer Upon access from the Menu one of the following is displayed OFF solid and 0 00 if no time was previously set ON and the remaining CD Time min sec if running OFF flash...

Page 41: ...102 Graphics SEt d and MENU with selections USE DEFAULT no change to the display ADD CD TIMER replaces EDT The default screen for dives displays Current Depth NDC EDT and Temperature Set D adds CDT e...

Page 42: ...be restored after the audible FREE EDT Alarm When set ON the EDT alarm activates every 30 seconds during a dive The Audible will sound during which time the EDT Time digits will flash on the Main Fig...

Page 43: ...siological changes associated with the high pressures that competitive type Free diving can expose a diver to WARNINGS Ensure that you know which Operating Mode is selected NORM GAUG or FREE prior to...

Page 44: ...44 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 COMPASS MODE...

Page 45: ...in back to Face Down if Failed or FAILED S 2 sec save display as OP Main REF Menu SET REVERSE A 2 sec back to OP Main S 2 sec Reverse Heading S 2 sec S 2 sec Lock Bearing Confirm Reverse S 2 sec displ...

Page 46: ...n action 2 min to revert to Surface or Dive Main NORTH OP MAIN information includes Fig 116 Current Depth with FT or M icon Surface Interval during first 10 min on surface blank on surface 10 min Nort...

Page 47: ...s to Calibrate the Compass before its first use after purchase before use in new global regions or if inac curacies are experienced Calibration will be required when the battery is changed Upon select...

Page 48: ...Menu If DECLIN EAST or WEST is selected that graphic will flash and the numeric value with icon will flash in place of the graphic MENU Fig 126 A 2 sec to increase Set Points one at a time from 0 to 4...

Page 49: ...When the procedure provided in this section is used to change the VT 4 0 Battery you must be sure that the case o ring is not pinched and that the VT 4 0 is water tight before conducting diving actvi...

Page 50: ...e VT 4 0 and is prepared for Upload of settings or Download of data which is then initiated using the PC OceanLog program Prior to attempting to Download data from your VT 4 0 or Upload settings to it...

Page 51: ...insured using a traceable method Non warranty service must be prepaid COD is not accepted Additional information is available on the Oceanic web site OceanicWorldwide com or on the local Oceanic web s...

Page 52: ...c Dealer Use of any other O ring will void the warranty Lightly lubricate the new Cover O ring with silicone grease and place it on the inner rim of the Battery Cover Fig 137a and ensure that it is ev...

Page 53: ...clockwise slowly by hand to ensure proper threading Apply a coin and tighten until secure The outer surface of the Battery Cover should be flush with the outer surface of the housing Fig 144 INSTALLIN...

Page 54: ...t to the factory for evaluation prior to further use If the VT 4 0 Resets i e is On turns Off then turns On again for any reason during any dive Nitrogen O2 and ATR calcula tions are terminated upon t...

Page 55: ...55 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 TECHNICAL DATA...

Page 56: ...4 4 4 4 48 6 5 5 4 4 4 4 4 4 3 3 3 51 5 4 4 4 4 4 4 3 3 3 3 3 54 5 4 4 4 4 3 3 3 3 3 3 3 57 5 4 4 3 3 3 3 3 3 3 3 3 DSAT ALGORITHM NDLS minutes at ALTITUDE Imperial Altitude 0 3001 4001 5001 6001 7001...

Page 57: ...dives conducted Dive Counter NORM GAUG displays Dives 1 to 24 FREE displays 1 to 99 0 if no dive made yet Resets to Dive 1 upon diving after 24 hours with no dives Dive Log Mode Stores 24 most recent...

Page 58: ...portant reason for not pushing the no decompression and oxygen exposure limits and a critical reason to avoid entering decompression If you dive in situations where your trip would be ruined or your s...

Page 59: ...e ___________________________________________________________________________________________________ Purchased from ___________________________________________________________________________________...

Page 60: ...60 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 VT 4 0 DIVE COMPUTER OPERATING MANUAL...

Reviews: