CARE AND CLEANING
Protect your unit from shock, excessive temperatures, exposure to chemicals, and tampering. Protect the lens against scratches
with a Instrument Lens Protector. Small scratches will naturally disappear underwater.
• Soak and rinse the VT 4.0 in fresh water at the end of each day of diving, and check to ensure that the areas around the
low pressure (depth) sensor (Fig. 133a), PC interface data port (Fig. 133b), and buttons are free of debris or obstructions.
Soak and rinse the regulator with the transmitter attached.
• To dissolve salt crystals, use lukewarm water or a slightly acidic bath (50% white vinegar/50% fresh water). After removal
from the bath, place the VT 4.0 and the regulator assembly with transmitter under gently running water and towel dry before
storing.
• Transport your VT 4.0 system cool, dry, and protected.
INSPECTIONS AND SERVICE
Your VT 4.0 should be inspected annually
by an Authorized Oceanic Dealer who will perform a factory prescribed function
check and inspection for damage or wear. To keep the 2 year limited warranty in effect, this inspection must be completed one
year after purchase (+/- 30 days).
Oceanic recommends that you continue to have an inspection performed every year to ensure it is working properly.
The costs of annual inspections, or inspections relating to water tight integrity, are not covered under the terms of the 2 year limited warranty.
To Obtain Service:
Take your VT 4.0 to your local Authorized Oceanic Dealer.
If required to return your VT 4.0 to the Oceanic USA factory:
• Obtain an RA (Return Authorization) number by contacting Oceanic USA at 510/562-0500 or send an e-mail to service@
oceanicusa.com.
• Record all dive data in the Log and/or download the data stored in memory. All data will be erased during factory service.
• Package it using a protective cushioning material.
• Include a legible note stating the specific reason for return, your name, address, daytime phone number, serial number(s),
and a copy of your original sales
receipt and Warranty Registration.
• Send freight prepaid and insured using a traceable method.
• Non-warranty service must be prepaid. COD is not accepted.
• Additional information is available on the Oceanic web site OceanicWorldwide.com or on the local Oceanic web site that
serves your global region.
BATTERY REPLACEMENT
The procedures that follow must be closely adhered to to avoid entrance of water into the unit. Dam-
age due to improper Battery replacement (or subsequent leakage of moisture into the unit) is not
covered by the VT 4.0's 2 year warranty.
When replacing the Battery in the VT 4.0, it is recommended that you also consider
replacing the Battery(s) in the Transmitter(s) to be used, and vice-versa.
The Battery Compartment should only be opened in a dry and clean environment with extreme care taken to prevent the entrance
of moisture or dust.
As an additional precautionary measure to prevent formation of moisture in the Battery Compartment, it is recommended that the
Battery be changed in an environment equivalent to the local outdoor temperature and humidity (e.g., do not change the Battery
in an air conditioned environment then take it outside during a hot sunny day).
Inspect the Buttons, Lens, and Housing to ensure they are not cracked or damaged. If there is any sign of moisture inside the unit,
DO NOT attempt to use it for diving until it receives proper service by the Oceanic factory or an Authorized Regional Facility.
Data Retention
When the battery is removed, settings* and calculations for repetitive dives are retained in volatile memory until a new battery is
installed. You will have the choice of saving or deleting the data (see page xx).
*Date will have to be set, Time may require adjustment for the time duration that the battery remains out of the unit.
Battery Cover Removal
• Locate the Battery Compartment on the back of the module.
• While applying steady inward pressure on the clear Battery Cover, rotate the Cover Ring clockwise 10 degrees by pressing
on the upper/right arm of the Ring with a small blade screwdriver (Fig. 134A).
If available, an adjustable face spanner tool or pointed pliers can be used by inserting the tips of the tool in the small holes in
the Ring, then push and turn (Fig. 134B).
• Lift the Cover Ring up and away from the Housing.
• Remove the clear Battery Cover.
Fig. 133 - VT 4.0 CASE BACK
b
a
Fig. 134 - COVER REMOVAL
A
B
Summary of Contents for VT 4.0
Page 4: ...4 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 FEATURES FUNCTIONS...
Page 10: ...10 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 NORM SURFACE MODES...
Page 19: ...19 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 DIVE MODE FEATURES...
Page 24: ...24 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 NORM DIVE MODES...
Page 31: ...31 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 GAS TMT SWITCHING...
Page 34: ...34 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 GAUG OP MODE...
Page 39: ...39 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 FREE DIVE OP MODE...
Page 44: ...44 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 COMPASS MODE...
Page 55: ...55 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 TECHNICAL DATA...