background image

56

VT 4.0 OPERATING MANUAL

© 2002 Design, 2011

Doc. No. 12-5213-r02 (9/6/11)

PZ+ ALGORITHM >> NDLS (minutes) at ALTITUDE (Imperial)

Altitude 

3001 

4001 

5001 

6001 

7001 

8001 

9001 

10001 

11001 

12001 

13001

(feet) 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

   

3000 

4000 

5000 

6000 

7000 

8000 

9000 

10000 

11000 

12000 

13000 

14000

Depth

( FT )

30  

197 

150 

141 

134 

128 

122 

117 

112 

107 

99 

94 

89

40  

109 

81 

75 

71 

68 

65 

62 

60 

57 

55 

53 

51

50  

65 

53 

51 

49 

47 

44 

42 

39 

37 

35 

34 

33

60  

48 

37 

35 

33 

32 

30 

28 

26 

24 

23 

22 

21

70  

35 

26 

24 

23 

21 

20 

19 

18 

17 

16 

16 

14

80  

26 

19 

18 

17 

16 

15 

14 

13 

12 

11 

11 

10

90  

19 

15 

14 

13 

12 

11 

10 

10 

8

100 

16 

11 

10 

10 

110 

12 

5

120 

10 

5

130 

4

140 

4

150 

3

160 

3

170 

3

180 

3

190 

3

PZ+ ALGORITHM >> NDLS (minutes) at ALTITUDE (Metric)

Altitude   

916 

1221 

1526 

1831 

2136 

2441 

2746 

3051 

3356 

3661 

3966

(meters)   

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

   

 

915 

1220 

1525 

1830 

2135 

2440 

2745 

3050 

3355 

3660 

3965 

4270

Depth

( M )

9   

 

217 

161 

151 

143 

136 

130 

124 

119 

104 

110 

103 

97

12  

 

115 

87 

81 

75 

72 

68 

65 

63 

60 

58 

55 

54

15  

 

68 

55 

53 

51 

49 

47 

44 

42 

39 

37 

36 

34

18  

 

50 

39 

37 

35 

33 

32 

30 

28 

26 

24 

23 

22

21  

 

36 

28 

26 

24 

23 

21 

20 

19 

18 

17 

16 

16

24  

 

27 

20 

19 

18 

17 

16 

15 

14 

13 

12 

11 

11

27  

 

20 

16 

15 

13 

12 

11 

11 

10 

8

30  

 

16 

12 

11 

10 

7

33  

 

13 

6

36  

 

10 

5

39  

 

4

42  

 

4

45  

 

4

48  

 

3

51  

 

3

54  

 

3

57  

 

3

DSAT ALGORITHM >> NDLS (minutes) at ALTITUDE (Imperial)

Altitude  0 

3001 

4001 

5001 

6001 

7001 

8001 

9001 

10001 

11001 

12001 

13001

(feet) 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

   

3000 

4000 

5000 

6000 

7000 

8000 

9000 

10000 

11000 

12000 

13000 

14000

Depth

( FT )

30  

260   

201 

187 

175 

165 

156 

148 

141 

135 

130 

124 

118

40  

137   

103 

96 

90 

85 

80 

76 

72 

69 

66 

63 

61

50  

81 

 

63 

60 

58 

55 

52 

48 

45 

43 

41 

39 

37

60  

57 

 

43 

40 

38 

36 

34 

33 

31 

30 

29 

28 

27

70  

40 

 

31 

30 

28 

27 

26 

24 

23 

22 

20 

19 

18

80  

30 

 

24 

23 

21 

20 

19 

18 

17 

16 

16 

14 

13

90  

24 

 

19 

18 

17 

16 

15 

14 

13 

12 

11 

10 

10

100 

19 

15 

14 

13 

12 

11 

10 

10 

8

110 

16 

12 

11 

10 

7

120 

13 

6

130 

11 

5

140 

5

150 

4

160 

4

170 

3

180 

3

190 

3

DSAT ALGORITHM >> NDLS (minutes) at ALTITUDE (Metric)

Altitude  0 

916 

1221 

1526 

1831 

2136 

2441 

2746 

3051 

3356 

3661 

3966

(meters)  to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

   

915 

1220 

1525 

1830 

2135 

2440 

2745 

3050 

3355 

3660 

3965 

4270

Depth

( M )

9    

283 

217 

204 

190 

178 

168 

159 

151 

144 

138 

132 

127

12  

144 

112 

104 

97 

90 

85 

81 

77 

73 

70 

67 

64

15  

85 

66 

63 

60 

57 

55 

52 

49 

46 

43 

41 

39

18  

59 

45 

42 

40 

38 

36 

34 

32 

31 

30 

29 

28

21  

41 

33 

31 

29 

28 

27 

26 

24 

23 

21 

20 

19

24  

32 

26 

24 

22 

21 

20 

19 

18 

17 

16 

15 

14

27  

25 

19 

18 

17 

16 

16 

14 

13 

12 

12 

11 

10

30  

20 

16 

15 

13 

12 

12 

11 

10 

10 

8

33  

17 

12 

11 

11 

10 

7

36  

14 

10 

6

39  

11 

5

42  

5

45  

4

48  

4

51  

4

54  

3

57  

3

Summary of Contents for VT 4.0

Page 1: ...1 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 VT 4 0 DIVE COMPUTER OPERATING MANUAL...

Page 2: ...SAFETY STOP 22 DIVE TIME REMAINING DTR 22 No Deco DTR NDC 22 O2 DTR OTR 22 AIR TIME REMAINING ATR 23 NORM Dive Mode Structure 23 NORM DIVE MODES 24 NO DECO MAIN AND ALTS 25 DEEP STOP DS 26 SAFETY STOP...

Page 3: ...Dive Computer with Free Dive Mode and or Wireless Data Transmission U S Patent no 7 797 124 Air Time Remaining U S Patent no 4 586 136 and 6 543 444 and Data Sensing and Processing Device U S Patent...

Page 4: ...4 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 FEATURES FUNCTIONS...

Page 5: ...ithm type DTR Dive Time Remaining DURA Duration backlight E East compass EDT Elapsed Dive Time EL Elevation altitude FO2 Fraction of Oxygen FORM Format date time FREE Free Dive Mode FT Feet depth GAUG...

Page 6: ...to display alpha numeric messages and measured values as well as Menu type systems for selection of settings and various auxiliary functions It also serves as the Digital Compass which can be accesse...

Page 7: ...rt beeps which cannot be disabled sound when Ascent Rate is 51 to 60 FPM 15 1 to 18 MPM when deeper than 60 FT 18 M or 26 to 30 FPM 7 5 to 9 MPM at 60 FT 18 M and shallower FREE Dive Elapsed Dive Time...

Page 8: ...ttery icon shell only will flash for 5 seconds then the unit shuts off completely VT 4 0 LOW BATTERY DURING A DIVE 2 75 volts warning level Backlight is completely disabled All other functions continu...

Page 9: ...able until a Transition time elapses The reason for this is that making a descent during the first 10 minutes after surfacing from a NORM or GAUG dive or the first 1 minute after surfacing from a FREE...

Page 10: ...10 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 NORM SURFACE MODES...

Page 11: ...2 sec to activate Backlight NORM SURF ALT 2 information includes Fig 8 Altitude graphic if EL2 to EL7 blank if Sea level Time of Day hr min with graphic A or P Temperature with icon and graphic F or C...

Page 12: ...es of the next 3 000 foot 915 meter higher Altitude Refer to tables in back PDPS information includes Fig 11A B Plan Depth value with FT or M icon Nx and PZ icons if they apply Max Depth allowed with...

Page 13: ...when dive ended FO2 value set for Gas in used when dive ended with icon S 2 sec to revert to Log Menu S 2 sec at any time to revert to Log Menu NORM GAUG SET MENU The Set Menu selection provides acce...

Page 14: ...ed in the unit Graphic LCD with 01 or higher indicating the Display s revision number This number will change if Firmware is updated by factory service or by future download of revised firmware from t...

Page 15: ...2 Gas 1 is set for Nitrox 21 to 100 10 minutes on the surface after that dive the FO2 Gas 1 will be displayed as 50 and further dives will be calculated based on 50 O2 for oxygen calculations and 21 O...

Page 16: ...O DUR with Set Point 5 10 or 15 SEC time backlight remains on SAMPLE with Set Point 2 15 30 or 60 SEC rate data is recorded for PC download TO SET TMT MENU to access Set TMT menu These items apply to...

Page 17: ...flash the 2nd digit Repeat A M S button action until all digits are set with operation then reverting to the Set TMT Menu with SET solid SET T Time Date Menu information includes Graphics SEt t and ME...

Page 18: ...te A 2 sec to step forward down through selections M 2 sec to step back up through selections S 2 sec when the pointer icon is next a selection will save it as the Dive Main and revert to the Set Menu...

Page 19: ...19 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 DIVE MODE FEATURES...

Page 20: ...front of the TMT Best reception is achieved when the VT 4 0 is within less than 4 feet 1 2 meter of the TMT When installed into the high pressure ports of the Regulator First Stages the TMTs must be...

Page 21: ...sly and the TLBG displays the one that is in control of your dive at any given time VARI The VARI Fig 38b provides a visual representation of ascent speed i e an ascent speedometer The segments repres...

Page 22: ...it will be disabed for the remainder of that dive There is no Penalty if you surface prior to completing the SS or ignore it If set for Timer On Upon ascending to 20 FT 6 M for 1 second on a No Deco d...

Page 23: ...that you selected during setup End Pressure Alarm Setting ATR is displayed on the Dive Main screens Fig 42a ATR Alarm When ATR decreases to 5 minutes the Audible will sound and the ATR time digits an...

Page 24: ...24 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 NORM DIVE MODES...

Page 25: ...ccess Gas TMT Switching S 2 sec to activate Smartglo Backlight or acknowledge alarms S 2 sec to access Compass These items can only be accessed while viewing the Main No Deco Alt 1 information include...

Page 26: ...g 44 2 is similar to No Deco ALT 1 Fig 45 3 is similar to No Deco ALT 2 Fig 46 4 is similar to No Deco ALT 3 Fig 47 SAFETY STOP MAIN information includes Fig 50A B Current Depth with FT or M icon Nx P...

Page 27: ...N information includes Fig 52 Current Depth with FT or M icon Nx PZ CF icons if they apply Graphic DECO STOP with Stop icon arrows and bar Stop Depth with graphic FT or M and Stop Time up to 599 min w...

Page 28: ...TLBG will flash Two Up Arrows will also flash until within 10 FT 3 M of and below the required Stop Depth of 60 FT 18 M Once within 10 FT 3 M of and below the required Stop Depth the full Stop icon sm...

Page 29: ...vides the time remaining of the 24 hours required before normal operation can resume with full features and functions HIGH PO2 Warning at Alarm Set Point value minus 0 20 1 00 to 1 40 Alarm at Set Poi...

Page 30: ...end When O2 reaches 100 the Audible will sound again during which the O2 value 100 and 2 Up Arrows will flash until on the surface Fig 68 The full TLBG remains on solid as a reminder of Deco A 2 sec t...

Page 31: ...31 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 GAS TMT SWITCHING...

Page 32: ...d ATR will increase to maximum after 1 minute without a change in transmitted Pressure Gas Switch Alarm If a switch to the Gas would result in PO2 1 60 the Audible will sound and a warning message wil...

Page 33: ...LY LOG SET MENU OP MODE HISTORY VT 4 0 ID BATT TMT PREVIEW M 2 sec access selection ALTs GAUG DIVE S 2 sec DIVE MAIN M S A 2 sec 2 sec 2 sec 2 sec TMT Switch Compass Op Main Backlight Smartglo 60 sec...

Page 34: ...34 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 GAUG OP MODE...

Page 35: ...r P Temperature with icon and graphic F or C A 2 sec to access ALT 3 5 sec revert to Main if A is not pressed S 2 sec to activate Backlight GAUG SURF ALT 3 information includes Fig 83 Graphics GAUG an...

Page 36: ...can then be accessed directly by pressing M 2 sec while viewing the Surface Main A 2 sec to step forward down through selections M 2 sec to step back up through selections S 2 sec when the pointer ic...

Page 37: ...selections M 2 sec to step back through Menu selections S 2 sec when the pointer icon is next a selection will toggle it between solid and flashing Once 4 items are flashing another item cannot be to...

Page 38: ...th with MAX and FT or M icons if Run Timer is on Main Time of Day hr min with graphic A or P if 12 Hour Temperature with icon and graphic F or C A 2 sec to revert to Main Revert to Main in 5 sec if A...

Page 39: ...39 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 FREE DIVE OP MODE...

Page 40: ...ace Main CD TIMER Countdown Timer Upon access from the Menu one of the following is displayed OFF solid and 0 00 if no time was previously set ON and the remaining CD Time min sec if running OFF flash...

Page 41: ...102 Graphics SEt d and MENU with selections USE DEFAULT no change to the display ADD CD TIMER replaces EDT The default screen for dives displays Current Depth NDC EDT and Temperature Set D adds CDT e...

Page 42: ...be restored after the audible FREE EDT Alarm When set ON the EDT alarm activates every 30 seconds during a dive The Audible will sound during which time the EDT Time digits will flash on the Main Fig...

Page 43: ...siological changes associated with the high pressures that competitive type Free diving can expose a diver to WARNINGS Ensure that you know which Operating Mode is selected NORM GAUG or FREE prior to...

Page 44: ...44 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 COMPASS MODE...

Page 45: ...in back to Face Down if Failed or FAILED S 2 sec save display as OP Main REF Menu SET REVERSE A 2 sec back to OP Main S 2 sec Reverse Heading S 2 sec S 2 sec Lock Bearing Confirm Reverse S 2 sec displ...

Page 46: ...n action 2 min to revert to Surface or Dive Main NORTH OP MAIN information includes Fig 116 Current Depth with FT or M icon Surface Interval during first 10 min on surface blank on surface 10 min Nort...

Page 47: ...s to Calibrate the Compass before its first use after purchase before use in new global regions or if inac curacies are experienced Calibration will be required when the battery is changed Upon select...

Page 48: ...Menu If DECLIN EAST or WEST is selected that graphic will flash and the numeric value with icon will flash in place of the graphic MENU Fig 126 A 2 sec to increase Set Points one at a time from 0 to 4...

Page 49: ...When the procedure provided in this section is used to change the VT 4 0 Battery you must be sure that the case o ring is not pinched and that the VT 4 0 is water tight before conducting diving actvi...

Page 50: ...e VT 4 0 and is prepared for Upload of settings or Download of data which is then initiated using the PC OceanLog program Prior to attempting to Download data from your VT 4 0 or Upload settings to it...

Page 51: ...insured using a traceable method Non warranty service must be prepaid COD is not accepted Additional information is available on the Oceanic web site OceanicWorldwide com or on the local Oceanic web s...

Page 52: ...c Dealer Use of any other O ring will void the warranty Lightly lubricate the new Cover O ring with silicone grease and place it on the inner rim of the Battery Cover Fig 137a and ensure that it is ev...

Page 53: ...clockwise slowly by hand to ensure proper threading Apply a coin and tighten until secure The outer surface of the Battery Cover should be flush with the outer surface of the housing Fig 144 INSTALLIN...

Page 54: ...t to the factory for evaluation prior to further use If the VT 4 0 Resets i e is On turns Off then turns On again for any reason during any dive Nitrogen O2 and ATR calcula tions are terminated upon t...

Page 55: ...55 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 TECHNICAL DATA...

Page 56: ...4 4 4 4 48 6 5 5 4 4 4 4 4 4 3 3 3 51 5 4 4 4 4 4 4 3 3 3 3 3 54 5 4 4 4 4 3 3 3 3 3 3 3 57 5 4 4 3 3 3 3 3 3 3 3 3 DSAT ALGORITHM NDLS minutes at ALTITUDE Imperial Altitude 0 3001 4001 5001 6001 7001...

Page 57: ...dives conducted Dive Counter NORM GAUG displays Dives 1 to 24 FREE displays 1 to 99 0 if no dive made yet Resets to Dive 1 upon diving after 24 hours with no dives Dive Log Mode Stores 24 most recent...

Page 58: ...portant reason for not pushing the no decompression and oxygen exposure limits and a critical reason to avoid entering decompression If you dive in situations where your trip would be ruined or your s...

Page 59: ...e ___________________________________________________________________________________________________ Purchased from ___________________________________________________________________________________...

Page 60: ...60 VT 4 0 OPERATING MANUAL 2002 Design 2011 Doc No 12 5213 r02 9 6 11 VT 4 0 DIVE COMPUTER OPERATING MANUAL...

Reviews: