13
9.
Replace light cartridge into mounting tube assembly and secure with locking clip as shown in the image
below.
10.
Bonding
: The light
MUST
be attached to the vessels bonding / cathodic protection system. Connect
the bonding cable to either one of the two free holes on the C clips (3) and lock in place with the short
spare M6 locking screw provided (4). Tighten the bonding screw using a 5mm Allen key, applying
thread lock at point of thread contact with ‘C’ clip. Once fitted it mandatory to check that there is full
continuity between the vessels cathodic protection system and the outer bezel of the mounting tube
assembly (see bonding schematic – chapter 7 Appendix).
11.
See Chapter 5 for driver installation information.
MAINTENANCE
FOR TIPS ON REMOVING THE INSERT, PLEASE REFER TO THE MAINTENANCE AND REPAIR SECTION IN
THIS GUIDE.
OceanLED INSTALL / ALLURE / 240717 / 7.1