EXPLORE
E3
.
2021 INSTALL & OPERATION MANUAL
23
EXPLORE SERIES
PROBLEM
CHECK
CAUSE
FIX
Light does not
light up
Check that the electrical
connections between the light
and the supply cable have been
made correctly
Poor electrical
connection
Remake connection and seal
joint correctly
Check that the wiring polarity is
correct, red to positive and
black to negative
Polarity incorrect
Change the wiring polarity
and seal joint correctly
Check that there is power
supply to the light cable
connection
Poor electrical
connection
Trace the cables back,
checking at joints until break
has been located. Then rectify
the problem and seal joint
correctly
Check that the electrical
connections between the supply
cable and the light circuit
breaker or fuse have been
made correctly
Poor electrical
connection
Remake connection and seal
joint correctly
Check that the in-line fuse is
intact and not blown
Replace fuse
If fuse keeps blowing, then
there is a short circuit in the
light system that must be traced
and rectified. If no external short
can be located contact your
dealer
Exchange the interlink cable
(between light and power
supply) with one from a working
light
Light works, faulty cable
Contact your dealer for a
replacement cable
Check that the light supply
circuit breaker is closed, or the
fuse has not blown
Close circuit breaker /
replace fuse
If breaker / fuse keeps blowing,
then there is a short circuit in
the light system that must be
traced and rectified. If no
external short can be located
contact your dealer