4.4 Disassembling, cleaning and sanitizing of the discharge door
Warning: before disassembling the
discharge door, remember to stop and
unplug the machine.
12
11
10
9
8
7
6
5
4
3
2
1
1. Pull down all the distribution
handles, so they are in distribution
position.
2. Unscrew the four hand screws (1)
and remove the discharge door
from the machine.
3. Remove the o-rings (8).
4. Unscrew the pivot pin nut (10) and
remove the pivot pin (7).
Picture 16: discharge door assemble 2
5. Remove the distribution handles (2) and Distribution level (3) and screw them
apart.
6. Press out the drawn valves (4,5) and remove Draw valve O-ring (5.6).
7. Clean all the parts with lukewarm water and the place them in a container with
sanitizing solution for 10 min.
8. Rinse the parts in cold drinking water.
9. Dry the parts with air or a clean towel.
10. Reassemble the discharge door and replace it.
NOTE. Remember to put a thin layer of lubricant on the different o-rings after they
have been put in place.
Picture 17:dicharge door lubrication
Picture 18: drawn valves lubrication
22
Summary of Contents for OPF130
Page 5: ...Chapter 1 General information 5...
Page 11: ...Chapter 2 INSTALLATION 11...
Page 15: ...Chapter 3 OPERATING INSTRUKTION 15...
Page 19: ...Chapter 4 CLEANING AND SANITIZING 19...
Page 24: ...Chapter 5 TROUBLESHOOTING GUIDE 24...
Page 28: ...2 Follow the mixing rate according to the manufacturer 3 Try to always use fresh mix 28...