Document UT-MT-0428
Page 17 of 35
Edition 11/03/2014
Supersedes edition 04/30/2012
INSET RUNWAY EDGE LIGHT SLRE
INSTRUCTION MANUAL FOR USE, INSTALLATION AND MAINTENANCE
A gasket (separately supplied) must be placed between base and fixture for
watertightness: for 12” fixtures (Figure 10 - n°7) placed in the relevant shallow base
groove.
The 12” shallow base is 320 mm in diameter and 150 mm high.
On request, special bases without cable leads can be supplied, provided with holes
suitable for conduit connections.
Inside the base two suitable holders (Figure 10 - n°9) are provided to properly sustain
the secondary power cable, in case of this cable is inside incoming through a conduit.
3
INSTALLATION
3.1
Pavement Boring and Sawcutting
Drill each recess in pavement following the instruction in Figure .
Figure 11 – Pavement Boring, Sawcutting and Joint Intersection Details
Make sure the recess size and depth are maintained within the specified limits. All
surfaces of the recess must be clean and dry. If any of these surfaces is damp, it is
desirable that it be dried and blown clean with a compressed air blast. The recess
side walls must be perpendicular to the pavement surface. The bottom surface must