SPECIFICATIONS 

The EBA-75 has been designed to provide respiratory protection during escape from oxygen deficient 
or hazardous atmospheres.  This device enables the user to breathe independently of the ambient 
atmosphere for a minimum period of 60 minutes. 

Performance Data 

Capacity 
 

110 liters of oxygen 

Note: proper use of the device for "User at Rest" - 6.5 hours maximum 

 
Dimensions 
 

21.8 x 30.2 x 11.7 cm (8.6 x 11.9 x 4.6 in) 

 
Weight 
 

8 lbs. (carry in operation) 

 
Operating Environment 

Minimum operating temperature 32

˚F (0˚C) 

 

Nominal cylinder pressure 

– 2000 to 2500 psi. 

Service life 

The EBA-75 is designed for a service life of fifteen years if properly inspected and if the conditions of 
use are observed. 

A Mandatory Factory Service action shall occur ten years from the date of manufacture if the units 
have been stored and five years from the date of manufacture if the units have been carried.  The end 
of service life for the EBA-75 is fifteen years from the date of manufacture regardless of the 
deployment method. 

The Conditions of Use for the EBA-75 are: 

A. Daily and 90-Day Inspections as defined in this manual. 

B. Caring for the EBA-75 as defined in this manual. 

C. Acceptable Storage of the EBA-75: the EBA-75 must be stored in an Ocenco approved 
 

carry case and securely fastened to a wall or other substantial structure. Devices stored on 

 

vehicles must be secured against movement in a fully enclosed metal container. 

D. Acceptable Carry of the EBA-75: the EBA-75 must be carried in an Ocenco approved carry 
 

case. 

Scrubber life is limited to one escape event or one oxygen charge. 

 
NOTE: 

If escape is necessary don the device regardless of temperature. 

 

DISPOSAL

 

Safe disposal is necessary after the EBA-75 has been used, fails inspection, or has exceeded the 
fifteen year service life. Ocenco EBA-75s must be disposed of in accordance with hazardous material 
disposal regulations. 

Summary of Contents for EBA-75

Page 1: ...Page 1 of 13 INSTRUCTION MANUAL FOR THE EBA 75 CLOSED CIRCUIT ESCAPE RESPIRATOR CCER CAPACITY 3 Manual Number NH24053 Revision A ECN 3590 December 14 2015...

Page 2: ...EM DESCRIPTION OPERATION 3 OCENCO EBA 75 FUNCTIONAL DIAGRAM 4 INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE FOR USER AT REST 5 INSPECTION MAINTENANCE 6 INSPECTION CHECKLIST 7 OCENCO EBA 75 PARTS DIAGRAM...

Page 3: ...ecting the unit as explained in the Instructions for Use section on page 5 and the Inspection and Maintenance section on page 6 2 Avoid physical abuse to the unit 3 Follow all NIOSH and MSHA recommend...

Page 4: ...ves through the ON OFF valve into a pressure reducing regulator that reduces the oxygen pressure to 100 psi The oxygen then passes from the pressure reducing regulator through a hose and into the dema...

Page 5: ...r donning the goggles prescription eyeglasses can be donned by guiding the eyeglass temples through the channels provided 12 ESCAPE Proper handling maintenance and other information as supplied in thi...

Page 6: ...are provided one for each band If both seals are broken remove the unit from service 3 Inspect the apparatus for indications of abuse If the view through the case is obstructed such that a proper exam...

Page 7: ...astic loops that hold the handle straps 13 One or both of the two handle straps black nylon straps missing or broken 14 Inspect the factory service date label on the base and remove unit if past the m...

Page 8: ...13 5 PRESSUREGAUGE 4 MOUTHPIECE 3 GOGGLES 2 NOSECLIP 1 NECKHARNESS FROMLOW EREND OFSCRUBBER REGULATOR FROMDEMAND 6 11 MOUTHPIECE INHALATION 12 TO 5 7 3 4 1 ENDOFBREATHING FROMUPPER INHALATION 2 UPPER...

Page 9: ...HANDLE STRAP 18 BAND 17 LATCH SEALS 16 LATCH RELEASE RINGS 15 LATCH PIN REQUIRED HANDLE STRAP ATTACHED TO BASE OPTIONAL SHOULDER STRAP ATTACHED TO COVER 18 14 17 STORE XXXX CARRY XXXX MFG XXXX REQUIRE...

Page 10: ...from the date of manufacture if the units have been carried The end of service life for the EBA 75 is fifteen years from the date of manufacture regardless of the deployment method The Conditions of...

Page 11: ...th NIOSH Registration will enable NIOSH which approved this model of respirator to attempt to notify you if a problem is discovered that might affect the safety or performance of this respirator Regis...

Page 12: ...JMNO 1 PROTECTION SC Self contained ESC Escape CAP Capacity 2 CAUTIONS AND LIMITATIONS J Failure to properly use and maintain this product could result in injury or death M All approved respirators s...

Page 13: ...Page 13 of 13 LakeView Corporate Park 10225 82nd Avenue Pleasant Prairie Wisconsin 53158 5801 United States of America Telephone 262 947 9000 Telefacsimilie 262 947 9020 www ocenco com...

Reviews: