56
Ocmis Irrigazione S.p.A. – INSTRUCTION AND WARNING MANUAL – Translation of Original Instructions
MUMR-R1.02 .EN - 31/07/2015
CHAPTER 5 - Installation
5.6
CHECKS AND INSPECTIONS PRIOR TO STARTING UP
Prior to performing the operations for starting up the machine described in Chapter 6 below “USE AND OPERATION”, a series of general checks and
inspections need to be carried out, concerning mechanical assemblies and the oil hydraulic system, to prevent risks or operation issues.
DANGER
These checks and preparation to fi rst start-up must be performed by a skilled technician with the adequate skills and mechanics
and oil-hydraulics knowledge.
The checks and inspections listed below should be deemed normal maintenance operations, listed in detail under chapter 7 “MAINTENANCE”.
Upon successfully completing installation/placement of the machine and the checks set out in the manual and in this chapter, and prior to performing
any functional operation, the personnel in charge must carefully check and ensure all process valves are in the position shown in chapter 6.
CAUTION
It is strictly forbidden to operate the machine prior to ensuring the valves are in the position set out in chapter 6 (either open or
closed).
5.6.1
GENERAL CHECKS ON MECHANICAL ASSEMBLIES
Proceed with a general inspection of the mechanical part, specifi cally:
1. Perform a general visual inspection of the assemblies the machine consists of, ensuring there are no special mechanical abnormalities, foreign
matter in operating areas and that all components (actuators, raingun trolley, etc.) are properly fastened and securely positioned as set out in this
manual.
2. Ensure the mechanical assemblies are perfectly assembled and aligned, connected and fastened to their structure.
3. Check the tightening of screws and nuts of the machine's main components.
4. Ensure moving components are greased and able to move freely.
5. Ensure the area where the machine is placed is free from objects that may hinder its movement and that of the attending personnel.
6. Check the oil level in the turbo-gearbox.
7. Check the oil level of the internal combustion engine if the machine is equipped with it.
8. After performing the general inspections, start the procedures set out in chapter 6.
Please refer to the manuals for the installed components for the specifi c checks to be performed on them.
DANGER
The checks and inspections on mechanical assemblies are to be performed with the machine stationary and the power
disconnected.
5.6.2
CHECK ON SAFETY SYSTEMS
Prior to operating the machine, ensure it is correctly installed and that the fi xed guards and safety devices it is equipped with are correctly assembled
and operable.
Safety devices and relevant check procedures are described in Chapter 4 “SAFETY”.
NOTE
This procedure must be implemented as a standard maintenance procedure.
CAUTION
The machine's safety is not assured in the event that safety devices have been removed or tampered with.
Summary of Contents for MR
Page 99: ......