63
Ocmis Irrigazione S.p.A. – INSTRUCTION AND WARNING MANUAL – Translation of Original Instructions
MUMR-R1.02 .EN - 31/07/2015
CHAPTER 6 - Use and Operation
4) CHECKS TO BE PERFORMED FOR MACHINES FITTED WITH COMPUTER (OPTIONAL) - (STANDARD FOR R1AT15 )
•
Check correct cylinder distance (inductive sensor) from the outer diameter of the pinion teeth that transmits motion to the crown gear located on
the reel side.
2 mm. / 0,08 in
•
Turn on the computer and check proper operation.
•
To perform this test, refer to the specifi c Manual.
•
Check the proper operation of the limit Micro-switch only if the machine is equipped with the Rain Control computer.
In addition to the indications under (b) par. 6.2.2.2, the limit Micro-switch must send the end-of-work signal to the computer.
If this should not occur or occurs before the end of the procedure under (b) par. 6.2.2.2, the angle plate must be adjusted by turning left or right so
that is draws closer to or away from the fl exible rod on the micro-switch.
5)
CHECKS TO BE PERFORMED FOR MACHINES EQUIPPED WITH ELECTRONIC METRE COUNTER (OPTIONAL FEATURE)
Check correct cylinder distance (inductive sensor) from the head of the screw located on the PTO shaft.
2 mm. / 0,08 in
6) CHECKS TO BE PERFORMED FOR MACHINES EQUIPPED WITH (OPTIONAL) INLET AND/OR DISCHARGE VALVES
The valves must operate as follows:
a) The slow closing INLET valve must be:
OPEN, when the machine starts operating - CLOSED, when the machine fi nishes operating.
b) The DISCHARGE valve must be:
CLOSED, when the machine starts operating - OPEN, when the machine fi nishes operating.
MECHANICAL VALVES
a) MECHANICAL INLET VALVE
After unwinding the hose and before connecting water inlet
to the pumping station it is required to check the following:
- manually set lever L in the OPEN valve position ensuring
it has hooked onto the return bracket and to check that just release
the lever, which must remain in the OPEN valve position.
slowly pushing the COR as shown in the picture, one must ensure lever L
automatically moves to CLOSED valve position.
OPEN CLOSED
COR
L
Summary of Contents for MR
Page 99: ......