Ocmis Irrigazione S.p.A. – INSTRUCTION AND WARNING MANUAL – Translation of Original Instructions
MUMR-R1.02 .EN - 31/07/2015
CHAPTER 6 - Use and Operation
b) MECHANICAL DISCHARGE VALVE
After unwinding the hose and before connecting water inlet
to the pumping station it is required to check the following:
- when slowly pushing the COR as shown in the previous picture,
the slider CU must enable cock RU to open the DISCHARGE valve.
Computer controlled ELECTRICAL VALVES
a) COMPUTER-CONTROLLED ELECTRICAL INLET VALVE
Before connecting water inlet to the pumping station, simulate
end of work with the computer CO and ensure the same
enables solenoid valve to close the INLET valve.
a) COMPUTER-CONTROLLED ELECTRICAL DISCHARGE VALVE
Before connecting water inlet to the pumping station, simulate
end of work with the computer CO and ensure the same
enables solenoid valve EL to open the DISCHARGE valve.
Note: Should the above operations not take place, ensure there are no faults in electrical connections and that there is enough electricity in the battery.
CU
RU
CO
EL
CO
EL