15.2.4 TIME
Navigate through the MENU button < > to the TIME (clock symbol).
Press ENTER. The indication 00:00 will appear on the screen. The first part will be blinking.
Press the EDIT b, - to insert the time in hours (0 to 24).
Press the Menu button < > to move to the second part.
Press the EDIT b, - to insert the time in minutes (0 to 60).
Press ENTER to set the time. The command will be stored and you can move on.
15.2.5 PROGRAMMING
The programming has thirteen (13) submenus. These are:
1
OFF,
useful only to the technician. (Always set to OFF).
2
SCREEN BRIGHTNESS (1 to 5)
3
CHANGING DISPLAY STATUS OF LCD SCREEN
Press 1 for continuous rotation of display values
Press 2 for screen display of boiler water temperature
Press 3 for screen display of the time / water temperature
4
BEEPER VOLUME
5
HARDWARE TYPE AND SCREEN,
useful only to the technician.
6
MANUAL ACTIVATION OF AUGER
A particularly useful command for the filling of auger with fuel either at first start
up or after emptying the fuel tank.
7
UNLOCK OF PROGRAMMING to new parameter settings
This is ONLY allowed to a qualified licensed technician giving him access to
modify predefined settings Νο 8 to 13
8
SYSTEM PARAMETERS
e.g. fan speed
9
d In ,
to be adjusted only with manufacturer’s approval
10
Α In,
display of sensors’ current values (see §16.1.2)
11
DIGITAL OUTPUT,
to be adjusted only with manufacturer’s approval
12
STATISTICS OF BURNER’S USE
(manufacturer)
13
ERROR LOG REPORT
(manufacturer)
Navigate through the MENU button < > to the PROGRAMMING (gear symbol).
The indication OFF will appear on the screen.
Press EDIT b, - to choose the setting you wish to modify e.g. [ 2 ]* and press ENTER.
A number indicating the screen brightness e.g. 3 will appear on the screen.
Press EDIT b, - to choose the desired brightness and press ENTER.
The end user is only allowed to modify parameter settings 2, 3, 4 and 6 at the 1
st
level of
configuration of the burner.