Warranty 

Octagon Systems Corporation (Octagon) warrants that its standard hardware products will 
be free from defects in materials and workmanship under normal use and service for the 
current established warranty period. Octagon’s obligation under this warranty shall not arise 
until Buyer returns the defective product, freight prepaid to Octagon’s facility or another 
specified location. Octagon’s only responsibility under this warranty is, at its option, to 
replace or repair, free of charge, any defective component part of such products. 

Limitations on warranty 

The warranty set forth above does not extend to and shall not apply to: 
1.

 

Products, including software, which have been repaired or altered by other than 
Octagon personnel, unless Buyer has properly altered or repaired the products in 
accordance with procedures previously approved in writing by Octagon. 

2.

 

Products which have been subject to power supply reversal, misuse, neglect, 
accident, or improper installation. 

3.

 

The design, capability, capacity, or suitability for use of the Software. Software is 
licensed on an “AS IS” basis without warranty. 

The warranty and remedies set forth above are in lieu of all other warranties expressed or 
implied, oral or written, either in fact or by operation of law, statutory or otherwise, 
including warranties of merchantability and fitness for a particular purpose, which Octagon 
specifically disclaims. Octagon neither assumes nor authorizes any other liability in 
connection with the sale, installation or use of its products. Octagon shall have no liability 
for incidental or consequential damages of any kind arising out of the sale, delay in delivery, 
installation, or use of its products. 

Service policy 

1.

 

If a product should fail during the warranty period, it will be repaired free of 
charge. For out of warranty repairs, the customer will be invoiced for repair charges 
at current standard labor and materials rates. 

2.

 

If a product returned for repairs is found to be free of defect, customer might be 
liable for the minimum current repair charge. 

Returning a product for repair 

1.

 

The customer must call Tech Support at 1–303-426-4521 to determine if repair 
service is necessary. 

2.

 

If repair service is required, Tech Support will require the customer’s name, address, 
telephone number, email address and a list of problems found. 

3.

 

Tech Support will forward this information to the RMA Administrator who will 
contact the customer to issue the RMA number. 

4.

 

The customer must carefully package the product in an antistatic container. Failure 
to package in antistatic packaging will VOID all warranties. Then package in a safe 
container for shipping. 

5.

 

Write the RMA number on the outside of the shipping container. 

6.

 

The customer pays for shipping to Octagon. Octagon pays for shipping back to the 
customer. 

7.

 

Other conditions and limitations may apply to international shipments. 

 

Note 

PRODUCTS RETURNED TO OCTAGON FREIGHT COLLECT OR WITHOUT AN RMA 
NUMBER CANNOT BE ACCEPTED AND WILL BE RETURNED FREIGHT COLLECT. 

Summary of Contents for MOBL-D2

Page 1: ...ch Ranch Blvd Westminster CO 80021 5490 A Colorado Corporation MOBL D2 Technical Manual Document 9186 rev B12 CONTACT INFORMATION Front Desk 1 303 430 1500 Technical Support 1 303 426 4521 FastHelp octagonsystems com www octagonsystems com ...

Page 2: ... other right and makes no representations that the circuits are free from patent infringement Octagon makes no representation or warranty that such applications will be suitable for the use specified without further testing or modification Octagon Systems Corporation s general policy does not recommend the use of its products in life support applications where the failure or malfunction of a compo...

Page 3: ...m 6 Hard Drive Options 6 Expansion Options 6 Operating Systems 6 Installation 7 Recommended Installation Practices 7 Using the MOBL D2 10 Power 10 Ethernet 10 Audio 10 GPS 10 ANT1 ANT2 10 USB 10 Serial communication 10 VGA 11 Power Management 11 Digital I O 11 Status LEDs 12 Technical specifications 13 CPU FSB and SDRAM 13 BIOS 13 On board flash 13 Hard drive 13 USB 13 Serial I O 13 Digital I O 13...

Page 4: ...ct for repair 21 Product return Policies 22 Governing law 22 List of Figures Figure 1 Mounting hole and system dimensions inches mm 8 Figure 2 MOBL D2 case dimensions inches mm 9 Figure 3 Internal Connectors and Sockets 18 List of Tables Table 1 MOBL D2 Mating Connectors 15 Table 2 Power Connector Pin Out 15 Table 3 Display Connector Pin Out 16 Table 4 Ethernet Connector Pin Out 16 Table 5 Serial ...

Page 5: ...h the system is installed for fixed disk storage A Fifty Channel GPS receiver offers location and timing information The receiver supports 3 3V powered as well as passive antennas A Bluetooth interface is standard on the MOBL D2 and is provided with an external antenna connected to the front panel A rear panel USB port with tethered cover is provided for maintenance diagnostics updates or other te...

Page 6: ...ooks like a hard drive to the system This socket accepts Type I or Type II Compact Flash devices The Compact Flash feature is CF 3 0 compliant DMA capable and supports true IDE mode Octagon Systems only recommends industrial grade error correcting Compact Flash of the quality available with the system Expansion Options The MOBL D2 can be used in a stand alone mode or expanded through the Mini PCI ...

Page 7: ...a gauge and as short in length as practicable 6 The MOBL D2 is protected against transient voltages common in mobile applications It is required that an external in line fuse be used if a remote power supply is used This will prevent catastrophic damage from power supply reversal and sustained over voltage A fast actingfuse at 5A must be used 7 Proper ESD precautions and method must be followed wh...

Page 8: ...e and system dimensions inches mm CAUTION Do NOT remove loosen or tighten the screws attaching shock isolators to the mounting plat shown above Accidental damage to the shock isolators may result Refer any damaged mounting system to qualified repair personnel ...

Page 9: ...e 9 of 22 Figure 2 MOBL D2 case dimensions inches mm CAUTION Do NOT attempt to separate case from mounting plate Accidental damage to the shock isolators may result Refer any damaged mounting system to qualified repair personnel ...

Page 10: ... website ANT1 ANT2 There are 2 N antenna connectors provided for optional wireless communication modules Numerous communication formats are implemented with add on card such as PCI 104 Mini PCI An internal cable connects the card to the appropriate external connector USB The MOBL D2 provides two USB 2 0 ports on the front panel one in the Display connector and one in the Serial USB connector Addit...

Page 11: ...connected to power levels high state will cause the system to enter a standby low power state indicated by a yellow power LED on the front panel and will remain as long as ignition is applied Removal and reapplication of voltage to the ignition lead will restart the system If ignition should be removed long enough to initiate shutdown but returns before shutdown of the operating system is complete...

Page 12: ...yellow STAT is a user controlled bi color status LED Accessing the LED registers is accomplished through operating system drivers Contact Octagon Systems for driver availability and or a Board Support Package for your Operating System PWR is a Power indicator indicating On Green or Standby Yellow state of the power supply ...

Page 13: ...lash devices The MOBL D2 may also be expanded with external USB drives USB Two external ports are available from the front panel and one diagnostic service port on the rear panel All ports are USB 2 0 compliant Serial I O Two dedicated 2 wire RS 232 interfaces one dedicated 2 wire RS 485 interfaces IEC1000 level 3 ESD protection specification Contact discharge 6 kV Air gap discharge 8 kV Up to 115...

Page 14: ...ble Power input 9 36 VDC input 7W typical exclusive of expansion Environmental specifications Operating temperature 30 to 70 C Non operating temperature 55 to 95 C nonoperating Relative humidity 5 to 95 noncondensing Shock 20g 3 axis per MIL STD 810F Test Method 516 5 Functional shock test 4 5 2 20g peak Vibration Per MIL STD 810F Test Method 514 5 Annex A Category 20 for ground vehicles EMI CE Cl...

Page 15: ...M ports USB PT06E14 18PSR or similar DIG CAN Digital I O CAN Bus PT06E12 10PSR or similar External connector pin outs The following descriptions are as seen from the outside of the faceplate Table 2 Power Connector Pin Out Signal Name Pin PT02E1203P V_IN Voltage IN A GND_EXT Ex Gnd B IGNITION C Mating Connector PT06E12 3SSR The external power cable must be at least 18 gauge for cables of 0 75M or ...

Page 16: ... Connector PT06E14 19PSR Table 4 Ethernet Connector Pin Out Signal Name Pin Pin Signal Name PT02E106S A B C 10 6S F E D LAN Rx A D LAN Tx LAN Rx B E LAN Tx Shield ground C F Reserved Mating Connector PT06E10 6PSR Table 5 Serial USB Connector Pin Out Signal Name Pin Pin Signal Name PT02E1418S rear view 14 18S L A D R S H G P U T J B N M K C E F COM3 RX A K I 2 C GND COM3 TX B L COM1 RXD COM GND C M...

Page 17: ...tions Opening and closing the MOBL D2 box The back endplate of the MOBL D2 can be removed for access to the compact flash The bolts require a 4 mm hex wrench Access to the SIM card socket used with some cellular wireless WAN options and or access to the expansion connectors requires removal of the front plate CPU board as an assembly Contact Octagon Systems Technical Support for complete instructi...

Page 18: ...ows the connector and switch locations on the CPU Board Table 6 Internal Connectors and Sockets lists the connectors switches and functions Figure 3 Internal Connectors and Sockets CAUTION The internal connectors and cables described are for reference only No internal cable or component may be removed ...

Page 19: ...ed peripherals sometimes referred to as PCI Express Mini Card The socket in the MOBL D2 supports cards of this form factor with USB functions only PCI Express is not available with the standard CPU Octagon offers several modules such as GPRS or other Cellular communications devices which use this socket PCI 104 The PCI 104connector allows you to interface expansion modules such as A D converters C...

Page 20: ... Cable Power Input 3 lead cable with un terminated end 8339 Quickstart AC DC Power Supply Provides power from AC line 7509101 Cable Display VGA USB display cable 7508943 Cable Tough Touch For connecting touch screen 7509133 Cable Serial USB I O Breakout cable 7508945 Cable LAN RJ 45 to MOBL D LAN cable 7508944 Cable DIG CAN I O Breakout cable 7508946 Compact Flash Fixed Storage Medium Various opti...

Page 21: ...ically disclaims Octagon neither assumes nor authorizes any other liability in connection with the sale installation or use of its products Octagon shall have no liability for incidental or consequential damages of any kind arising out of the sale delay in delivery installation or use of its products Service policy 1 If a product should fail during the warranty period it will be repaired free of c...

Page 22: ...urn Governing law This agreement is made in governed by and shall be construed in accordance with the laws of the State of Colorado The information in this manual is provided for reference only Octagon does not assume any liability arising out of the application or use of the information or products described in this manual This manual may contain or reference information and products protected by...

Reviews: