10
i.
Select a primary contact plate (g) that matches the contour
of the top of the plastic grip (closest to a user). Peel the
blue protective film off of the tab on the primary contact
plate (g), then slide the tab into the connector at the end
of the small white wire.
j.
Select a secondary contact plate (h) that matches the
contour of the bottom of the plastic grip (away from the
user). Peel the blue protecting film off of the tab on the
secondary contact plate (h) and slide the tab into the
connector at the end of the remaining wire.
k.
Repeat steps (f) through (k) for the right handlebar.
l.
Push any extra lengths of wire into the mast tube.
m. Insert the connector at the end of the heart rate cable into
its connector on the heart rate board on the back of the
keypad.
(This is a two-wire cable ending in a single
connector.)
Route the contact heart rate cable wires
around the posts on the back of the keypad, in the same
manner that the other heart rate cable is routed (see figure
at right).
n. Route the cable from the other end of the heart rate board
down through the top of the mast tube and out of the hole
beneath the console plate.
o. Route the red and white fan wires with the white connector
down through the top of the mast tube and out of the hole
beneath the console plate.
p.
Attach the black ribbon cable connector from the keypad
(2) to its cable coming from the top of the mast.
Tug
the cables gently to ensure the connectors are
completely seated.
q. Position the keypad (2) on the mast (B) and insert each of
the 4 shorter screws with washers through the mast holes
and into the keypad back. Tighten screws to secure.
r. Remove the film from the adhesives on the primary
contact plates (g) and secondary contact plates (h)
and carefully press the plates onto the grips, pushing
the tabs, connectors, and wires inside the grips.
It is recommended that you wait to adhere the grips
until after you have installed the console and verified
that the contact heart rate grips are transmitting a
reading to the console.
Console/Keypad
Connection
(all models)
Standard
Heart Rate
Connection—
Q47e/Q47ce only
Contact Heart Rate
Connection—
Q47ce only
Fan Wire—
Q47e/Q47ce only
Keypad Ground
Connection
(all models)
Route
Contact Heart Rate Cables
Here
Contact Heart Rate Board
Connector for
Grip Wire
Note: If you are using the optional LCD Mounting Arm,
skip step 6 of these instructions and instead follow the
instructions included with the LCD Mounting Arm. Once
you have completed those instructions, resume assembly
of your Q47e/Q47ce with step 7 of these instructions.