Basics
5
www.ocularrobotics.com
Ocular Robotics Ltd
NOTE
- Make sure the power supply is not powered before
connecting the cables.
4.
Connect the power supply cable to the corresponding plug on the RE08 CSE. Ensure
the correct orientation by aligning the polarization keys on the panel connector and
the plug. If forced in the incorrect orientation, damage to the system is likely to
result. Refer to Section 3.2 for further details.
2.5
Safety
The RobotEye RE08 3D Laser Scanning System is a Class 1M laser device which contains
a laser which emits invisible radiation.
The device complies with Laser Class 1M based on IEC 60825-1:2007 and does
not pose any significant risk to a naked human eye unless passed through
magnifying optics.
Protection Class 3. The device operates with a separated extra low voltage
(SELV) of 24 Volts DC.
The device may only be operated as intended and in faultless condition. Safety
and warning signs must not be removed.
The Scanning Unit is in accordance with Ingress Protection 67 (IP67). The
device is protected against dust and immersion in 1 meter of water for up to
30 minutes.
The CSE is in accordance with Ingress Protection 66 (IP66). The device is
protected against dust and water jets.
All instructions regarding safe operation of this system should be strictly followed.
The user is responsible for the safe operation and maintenance of this system at all
times.
The RE08 is NOT intended for use by inexperienced personnel.
Installers of laser sensors are responsible for ensuring their safe use in accordance
with all applicable regulations in the state, country or territory of use.
Ensure fiber optic cables are correctly installed before powering on the
System. Laser radiation emitted directly from the CSE may cause damage to
the naked eye.