Basics
9
www.ocularrobotics.com
Ocular Robotics Pty Ltd
e)
Use fasteners appropriate for your camera to fasten the camera to the mount and
then tighten the socket screws attaching the mount to the base of the REV25.
NOTE
– The screws fastening the camera to the universal camera
mount must be loosened before adjusting the focus.
f)
Attach the internal Ethernet cable from the enclosure camera Ethernet connector
to your GigE camera
g)
The two pin connector shown in Figure 3.4 makes 24 VDC available for camera
power connection; a suitable converter from 24V to your camera’s required
voltage will need to be provided.
h)
Follow the procedure in Section 3.5.3 to adjust the focus and aperture of the
camera.
i)
Replace the base using the eight countersunk socket screws and tension
correctly to maintain the integrity of the seal.
6.
Attach power and communications cables as appropriate for your camera.