General Description
14
www.ocularrobotics.com
Ocular Robotics Pty Ltd
Figure 3.2 – Power connector on the REV25 Enclosure
During connection of the power supply cable to the corresponding plug on the REV25
system, ensure the correct orientation by aligning the polarisation keys on the panel
connector and the plug. If forced in the incorrect orientation, damage to the system is
likely to result.
A 16A rated fuse is housed in the Schurter 3101-0110 fuseholder to prevent potential
damage to internal electrical components from power surges.
Figure 3.3 – Fuseholder on the REV25 Enclosure
Power to the camera inside the enclosure is provided via a Molex KK6471 two-way
connector. The red wire provides 24 VDC with respect to the black wire at 0 V. A
suitable voltage converter is required if the camera operates at a different voltage.
Figure 3.4 – Power connector for the camera