Power Cord Check
▌Provided power cord is 3-wire ground type.
If you use power cord from other brand, use Ground type.
And connect the power supply earth to load's GND.
Input AC Power Line Check
▌Product is designed for single phase AC 220V ±10% / 50~60Hz.
You can Set another input option.
Turn on the power and load will be set in the previous setting value.
Display Procedure on the LCD
▌
Display
"
ODA Technologies
"
▌Display "LP"
▌Annunciators of ERR, LMT, RMT, LOCK on front side are lit and go off.
▌During displaying above procedure, the instrument is initialized by stored in non-
volatile memory.
Default Setting Values (Last State Mode is under the disable state)
▌Remote Interface : RS-232C
▌A Memory : CC-0A, CV-0V
▌
After Power On
: "
**OFF - ISET**
"
▌B Memory : CC-0A, CV-0V
▌Voltage, Current Value : 0
▌Dynamic DUTY: 50%
▌Resistor: Minimum of Low Range
▌Dynamic DYN-CYCLING TIME: 0.0001s
▌Range: Low Range
▌STEP: 1
▌ KEY LOCK : OFF
▌REPEAT: 1
▌SLEW : 1
▌SEQ: START No. 1, Finish No. 100
1.Initially, Remote Interface is RS232C, Baud-rate is 9600bps.
2.Last State Mode is "SAFETY". You can change the setting in Factory Mode.
Note1
1-6. Check After Power On
1-5. Check Before Power ON
- 4 -