5.  Cut the supply cable, remove 

the already existing tube to 
replace it with the one provided 
in the box of the installation 
without visible wire. Make sure 
you keep enough wire to go 
through the tube and to plug 
into the junction box.

6.  Pass the supply cable through 

the tube provided for this  
purpose and pass the wire 
through the plate. 

7.  Remove the tube already 

present on the towel warmer 
and replace it with the tube 
available in the box provided 
for hard-wired installation. Rivet 
the base onto the nut with the 
fixing screw.

8.  The supply cable should exit 

from the rear of the product.

11. Press the button to turn it on  

or off, select on the timer  
2 or 4 hours.

10  Install the base  

with the screws.

9.  Connect the supply cable to the 

junction box and aim the plate in 
the junction box.

Summary of Contents for OD-0810

Page 1: ... start to work if you want to stop it press the button again The timer can be adjusted to 2 h hour or 4 h hour Press the button to select the right time Please turn it off and take the plug out from the outlet if you are not using it Client TOLERANCES FINI DE SURFACE 125 PROJECTION 1 16 01 003 0005 1 X XX XXX XXXX 1 ANGLE SAUF CONTRE INDICATION LES DIMENSIONS SONT EN POUCES C dessin classé compagn...

Page 2: ...upper tubes and secure it with the screws 2 Identify the location of the holes needed for the screws on the wall 3 Drill holes in the wall 5 Rivet the base onto the nut with fixing screw 6 Install the base with the screw 4 Install stopper with screw on the wall ...

Page 3: ...ly cable must exit at the rear of the product Hardwire installation instruction 1 Slide the tray into the upper tubes and secure it with the screws 2 Identify the location of the holes needed for the screws on the wall 3 Drill holes in the wall 4 Install stopper with screw on the wall ...

Page 4: ...s purpose and pass the wire through the plate 7 Remove the tube already present on the towel warmer and replace it with the tube available in the box provided for hard wired installation Rivet the base onto the nut with the fixing screw 8 The supply cable should exit from the rear of the product 11 Press the button to turn it on or off select on the timer 2 or 4 hours 10 Install the base with the ...

Page 5: ...of god accident catastrophe abuse negli gence improper installation use maintenance intensive variation of temperature exposures to chemicals or stains caused by diffe rents types of water such as ferrous or alkaline water etc The use of abrasives of any kind gritting scraper brushes or any other scouring object which can damage the surface of the pro duct is to be proscribe and will cancel the pr...