Maintenance Section
4.4 Preventative Maintenance, continued;
Preventative Maintenance, continued;
BATTERY:
ODB's units are supplied with "maintenance free" batter-
ies so there is no need to check fluid levels but the battery terminals
should be checked daily for corrosion. Remove any corrosion with a
wire brush and coat the terminals with light grease or petroleum jelly
to reduce the possibility of corrosion. Also check the battery cable for
wear all cable connections and battery tie downs to be certain that they
are not loose.
DRIVE BELT (if equipped):
The main drive belt should be checked
daily for cracks and for proper tension. If the belt shows any sign of
cracking it should be replaced immediately. The proper tension of the
belt should be approximately 1/2" deflection when applying a 8 pound
pull.
FASTENERS:
Fasteners should be checked weekly for the first 30
days and monthly thereafter. They must be in place at all times and
properly torqued. For general torque values see the torque chart at the
end of this section.
INSTRUMENT PANEL AND CIRCUIT BOARD:
The instrument panel
and circuit board should be cleaned with compressed air daily. Also the
circuit board connectors should be wiped clean and have nonconduc-
tive grease applied weekly to help maintain solid connections.
BOOM HYDRAULIC PUMP:
Check the fluid level daily. If fluid needs
to be added, automatic transmission fluid (ATF) is recommended.
Clean debris and oil off the solenoid and pump daily. A build up of
debris can cause premature failure to the pump. Check and tighten all
hydraulic fittings making sure there are no leaks.
8.
9.
10.
11.
12.
ALWAYS wear eye and hand protection when working with the bat-
tery.
Remove the negative battery cable before opening the belt guard.