Hoist Hydraulic Fluid and Filter:
The hoist hydraulic fluid and filter
should be changed every 100 hours of operation. The fluid should be
completely drained and fresh high quality
ISO 68 non-foaming
hydrau-
lic fluid should be added.
Exhaust Duct Gasket:
The 1.5" thick gasket should be checked for
wear every 200 hours. This gasket creates a tight seal between the box
container and the blower housing.
Axle Hangers:
The hanger bolts should be checked periodically for
tightness and wear.
Hydraulic Fittings:
Check all hydraulic fittings for leaks and tightness.
Any leak could become a hazard, fix immediately.