82
ODB COMPANY
800-446-9823
SKB700
Service Section
5.8.5 IQAN Error Codes, continued
Fully read and understand the entire owner's manual
before operating this equipment. Follow and obey all
safety guidelines. Call ODB for any questions.
The XA2 and XS2 modules are flexible exansion modules designed for controlling hydraulic systems
in vehicles and machinery.
The green LED indicates power on.
The yellow blinking LED on the top of the module indicates normal status. If there is an error detect-
ed, the IQAN module will indicate error status through the RED blinking LED. This gives an immedi-
ate diagnosis as to the nature of the error that has occured. (Fig. 5.30.5C)
XA2 and XS2 Error Codes
ERROR
# RED
FLASHES
# YELLOW
FLASHES
POSSIBLE CAUSE
None
0
long flashes
normal operation
On Screen
1
1
on screen
On Screen
2
1
on screen
CAN error
3
1
lost communication
Address Error
3
2
Address tag error
Memory error
4
1
Lost memory on MD3(screen)
Fatal Error
8
0
Possible dead battery in the
screen
Figure 5.30.5C