RTP Bridge User’s Guide
25(36)
8
Testing Verification Procedure
8.1
Testing Scheme 1
To test RTP Bridge please use the following connection scheme (See Figure 11):
Figure 11 RTP Bridge Testing Scheme 1
Notes to the scheme:
a.
The T1/E1Analyzer is run on an OTX board (e.g., on t2pp) connected to Li0 of
the Alvis Board.
b.
The RTP Bridge sets RTP connection on a loopback IP-address 127.0.0.1.
c.
Alvis Board should be one of the following OTX boards:
Alvis-2-CSI
Alvis-4-CSI
Alvis-4M-CSI
Alvis-8-CSI
Alvis-8M-CSI
Alvis-ASM
Alvis-PCIe
Alvis-2-PBX
1.
Update the rpm repository packets list at Alvis Board:
apt-get update
2.
Install RTP Bridge package at Alvis Board with a command:
apt-get install rtpbridge
3.
Reset Linux file buffers at Alvis Board with a command:
sync
Doc. No. 1412-1-SAA-1020-1
www.odints.com
Rev. 1.9
Copyright © Odin TeleSystems Inc., 2010