IMPORTANT! 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the system. 

 

 

Always disconnect power from the mains, when system is not used. Only handle the power cord by 

the plug. Never pull out the plug by tugging the power cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 

same electrical circuit to ensure the same phase! 

 

Avoid installing your equipment very near radio or TV sets, mobile phones, etc., as these can cause 

RF (radio frequency) interference. 

 

Before changing your grounds around, always turn your amplifiers down. 

 

Before switching on or off, make sure that the sound system’s amplifiers are off or turned down: this 

will avoid signal peaks, which are annoying and sometimes dangerous (particularly for speaker 

enclosures). 

 

Do not connect this device to a dimmer pack. 

 

Do not open this device. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 

engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your system. Leave the 

system switched off until it has reached room temperature. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 

cord from time to time. 

 

Make sure that there is sufficient room on all sides of the system for air circulation. 

 

Make sure you do not use the wrong kind of cables or defective cables. 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 

connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Please turn off the power, when changing the power cord or signal cable, or select the input mode 

switch. 

 

Prevent distortion! Make sure that all components connected to the ODIN have sufficient power 

ratings. Otherwise distortion will be generated because the components are operated at their limits. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 

distributor. 

 

When connecting the other parts of your sound system, watch out for the so-called “ground loops”. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Summary of Contents for CL-4 Connect

Page 1: ...ODIN CL 4 Connect V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3915 MANUAL ENGLISH...

Page 2: ...eturn Procedure 4 Claims 4 Description of the device 5 Overview 5 Frontside 6 Backside 7 Installation 8 Connection Example 8 Set Up and Operation 9 Connecting a Wireless Access Point and Updating 9 Co...

Page 3: ...packing Your shipment includes ODIN CL 4 Connect 5V DC power adapter User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qua...

Page 4: ...ting If the system has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your system Leave the system...

Page 5: ...proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your...

Page 6: ...Line Array System There are 4 RJ45 ODIN data output ports for connecting up to 12 ODIN components per each output Power supply 5V DC 1000 mA Power consumption 5W Carrier frequency 2 4 GHz Data connec...

Page 7: ...ED indicators 1 4 The LEDs will blink when uninterrupted data transfer takes place LED LAN indicator Once a network has been established the LED will light up LED power indicator When the device is co...

Page 8: ...code D3915 ODIN CL 4 Connect Backside Fig 03 5V DC power connector IN RJ45 RC NET connectors 1 4 Connect your ODIN Line Array System RJ45 LAN connector IN Connect to a router in order to establish a n...

Page 9: ...ink on your first speaker to the audio signal input on your second speaker Repeat this step to connect multiple speakers 03 Using a PowerCON power cord connect the first speaker s power input to the p...

Page 10: ...PC to the CL 4 Connect via the wireless access point by connecting it to the router Follow the steps below 01 On the list of the available Wi Fi networks there will appear a new network named ODIN 02...

Page 11: ...can be found at the bottom 06 Once the connection has been established go to the Odin Editor The connection indicator should now light in green 07 Click on the CL 4 UPDATE button to open the window b...

Page 12: ...etc are caused entirely by using unsuitable or faulty cables For these applications the unit provides CAT 5 connectors to easily interface with most professional audio devices How to Make a Data Cabl...

Page 13: ...the unit operates properly do not carry out following steps 01 If the device does not operate properly unplug the device 02 Check the power from the wall all cables etc 03 If all of the above appears...

Page 14: ...13 Ordercode D3915 ODIN CL 4 Connect Notes...

Page 15: ...14 Ordercode D3915 ODIN CL 4 Connect...

Page 16: ...2016 ODIN...

Reviews: