background image

 

http://

 

www.odotautomation.com

   

         10 / 15            

TEL:

 

+86-0816-2538289

 

PWR2 

ON (RED)

 

Power supply 2 is normal 

OFF(RED)

 

Power supply 2 is 
abnormal 

 

 

 

 

2. Network port indicator LED 

5

口)

 

 

8 port

 

Link/Act

Link Status indication, Active: Active indicator 

ON

Link UP 

OFF

Link DOWN 

Flash

Active 

SHIELD

RJ45 Plug shield interface 

 

 

Summary of Contents for ODOT-MS105T

Page 1: ...http www odotautomation com 1 15 TEL 86 0816 2538289 Industrial Ethernet Switch ODOT MS105T 108T 116T User Manual V2 10 2021 02 01 ...

Page 2: ...2 15 TEL 86 0816 2538289 ODOT MS105T 108T 116T unmanaged ODOT Automation System Co Ltd 2021 02 Copyright 2021 ODOT Automation all rights reserved Version Information Date Version Content Author 2021 02 01 V1 00 Release version CCL ...

Page 3: ... the reader in using the products and the company shall not be responsible for any loss or error caused by the use of the information in this document The product and text described in this document are under constant development and refinement ODOT Automation System Co Ltd has the right to modify this document without notifying users Software download Please log on the official website www odotau...

Page 4: ...verview 5 1 1 Product Introduction 5 1 2 Function Introduction 5 1 3 System Parameter 6 2 Hardware description 7 2 1 Product appearance 7 2 2 Product identification drawing 8 2 3 Wiring diagram 8 2 4 LED indicator description 9 2 5 Installation size 12 3 Troubleshooting 14 ...

Page 5: ...ature range is 20 C to 70 C and it could be applied to a variety of industrial environments with standard 35mm DIN rail installation and its protection level is IP20 1 2 Function Introduction ODOT MS105T ODOT MS108T ODOT MS116T Support IEEE 802 3 802 3x 802 3u Input voltage 1 way 9 36V DC 2 way 9 36V DC Installation 35mm standard Din rail MAC address 2K 16K Support Auto negotiation 10 100Mbps half...

Page 6: ...t buffer area size 512bit 4MB Interface RJ45 port 10 100BaseT X auto sensing MDI MDIX auto negotiation Operating Conditions Temperature 20 70 Temperature 40 85 Power 9V 36V DC suggested 24V Overcurrent Protection 1 25A Anti reverse connection protection Support Anti reverse connection protection Electric Parameter ODOT MS105T ODOT MS108T ODOT MS116T Operating Voltage 9 36V DC Overcurrent Protectio...

Page 7: ...http www odotautomation com 7 15 TEL 86 0816 2538289 2 Hardware description 2 1 Product appearance Take ODOT MS105T as example ODOT MS108T ODOT MS116T is similar ...

Page 8: ...duct identification drawing Take ODOT MS116T as example ODOT MS105T ODOT MS108T is similar 2 3 Wiring diagram Table 2 3 1 ODOT MS105T wiring instruction Wiring port Wiring marking Wiring instruction 1 PE Earthing 2 V Power input negative 3 V Power input positive ...

Page 9: ... Wiring instruction 1 PE Earthing 2 V2 Power 2 input negative 3 V2 Power 2 input positive 4 PE Earthing 5 V1 Power 1 input negative 6 V1 Power 1 input positive 2 4 LED indicator description 1 Power LED Table 2 4 1 ODOT MS105T 108T LED instruction Marking Status Definition PWR ON RED Power supply is normal OFF RED Power supply is abnormal Table 2 4 2 ODOT MS116T LED instruction Marking Status Defin...

Page 10: ...2538289 PWR2 ON RED Power supply 2 is normal OFF RED Power supply 2 is abnormal 2 Network port indicator LED 5 口 8 port Link Act Link Status indication Active Active indicator ON Link UP OFF Link DOWN Flash Active SHIELD RJ45 Plug shield interface ...

Page 11: ...15 TEL 86 0816 2538289 16 port Speed Network speed indicator light multi color Green on 100Mbps Green off 10Mbps Link Act Link Status indication Active indicator ON Link UP OFF Link DOWN Flash Active SHIELD RJ45 Plug shield interface ...

Page 12: ...http www odotautomation com 12 15 TEL 86 0816 2538289 2 5 Installation size Table 2 5 1 ODOT MS105T Installation size ...

Page 13: ...http www odotautomation com 13 15 TEL 86 0816 2538289 Table 2 5 2 ODOT MS108T Installation size ...

Page 14: ...1 The PWR LED is off please check whether the switch power supply is normal 2 Insert the cable but the LED on the Ethernet port is not on Please check whether the plug at both ends of the cable have been firmly inserted and whether the cable is damaged ______________________________________________________________ ...

Page 15: ...ion com 15 15 TEL 86 0816 2538289 Odot Automation System Co Ltd Add No 6 Hongsheng Road Hi Tech District Mianyang Sichuan China Tel 86 0816 2538289 Zip Code 621000 Email sales odotautomation com Web www odotautomation com ...

Reviews: