131
If there is an error with the memory that stores the
user parameter, this alarm will occur.
Check and reset the recently-set parameter and
back up the remaining parameter.
If there is a parameter set-up out of the preset
range, this alarm will occur.
Reset the parameter with the values within the
preset range.
If the motor type or encoder type is incorrectly set,
this alarm will occur.
Set the encoder type (SEt-51), motor type (SEt-52),
and motor capacity (SEt-53) properly.
If there is a failure of the serial communication
caused by noise or connecting cable failure, this
alarm will occur.
Check the connection status of the cable and
connect it in a noise-free environment.
If there is an error with the memory that stores
parameter, this alarm will occur.
If this alarm occurs too often, replace the servo
drive with a new one.
If the rated output of the servo drive is incorrectly
set, this alarm will occur.