145
SEt-23 Encoder Output Ratio Numerator
•
Setting range: 1 to 65535
•
Factory Default: 2500
•
Changes while the servo is disable
The signal can be displayed after dividing the encoder input inside the
servo drive. This function can be used to make a position control loop
at the controller.
The formula to adjust the number of output pulses is as follows.
(Numerator/Denominator)
✕
Number of Encoder Pulse = Output to the
controller
If a certain type of the encoder connected to the drive produces 2048
pulses per revolution and as many as 1000 pulses per revolution
should be sent to the
controller
, the numerator can be set to 1000 and
the denominator can be set to 2048.
(1000/2048)
✕
2048 = 1000