Pipe heat tracing

GB

6

This product has been developed and manufactured for the sole use of preventing water pipes
from freezing. Improper installation, application and / or maintenance of the trace heating can re-
sult in fire, electric shock and / or freezing of pipes.

Warning: Use only on water supply pipes and according to these instructions. The minimum pipe

length is 2 m.

General information

Selection of the heating cable

Mounting notes

Mounting instructions

1

.0

2

.0

3

.0

4

.0

Tools and material required

Mounting to metal water pipes

Mounting to plastic water pipes

Maintenance

4.1

4.2

4.3

5

.0

7

8

9

9

6

6

7

7

Table of Contents

1

.0

General information

The anti-freeze heating cable should be long enough to run along the bottom of horizontal pipes or
along the weather-side of vertical pipes (including all valves) without crossing or spiralling.
To ensure a good thermal transfer, the heating cable should fit closely over the entire length of the
pipe. Never use a cable that is longer than the pipe to be protected.

2

.0

Selection of the heating cable

Summary of Contents for 118 572 151

Page 1: ...www oeg net D GB Rohrbegleitheizung Montage und Betriebsanweisung Pipe heat tracing Operation manual and spare parts list 118 572 151...

Page 2: ...ung Ben tigtes Werkzeug und Material 1 0 2 0 3 0 4 0 4 1 Montage an Wasserrohrleitung aus Metall Montage an Wasserrohrleitung aus Kunststoff Wartung 4 2 4 3 5 0 4 5 5 2 2 3 3 3 Inhalt 1 0 Allgemeine I...

Page 3: ...e Heizleitung nicht Wenn die Heizleitung verk rzt wird wird sie sich berhit zen Jegliche Manipulation oder Ver nderung an der Heizleitung f hrt zum Verlust der Gew hr leistung Einmal abgeschnitten kan...

Page 4: ...g platziert und mit einem hochwertigen Isolierband befestigt werden Das Thermostat sollte sich am k ltesten Ende des Rohres befinden Es erfasst die Temperatur des Rohres und schaltet die Heizleitung e...

Page 5: ...lle kontrollieren Stellen Sie bitte die Nutzung umgehend ein und entfer nen Sie das Ger t sobald es angeschnitten besch digt oder in Wasser getaucht ist ebenso wenn es Anzeichen von Verkohlung oder Ri...

Page 6: ...unting notes Mounting instructions 1 0 2 0 3 0 4 0 Tools and material required Mounting to metal water pipes Mounting to plastic water pipes Maintenance 4 1 4 2 4 3 5 0 7 8 9 9 6 6 7 7 Table of Conten...

Page 7: ...ke e g steam lines Do not modify the heating cable If made shorter it will overheat Any manipulation or attempt to modify the heating cable will void the warranty Once cut the heating cable cannot be...

Page 8: ...at at the end of the heating cable must be positioned tightly next to the pipe and should be mounted by means of a high quality insulation tape The thermostat should be located at the coldest end of t...

Page 9: ...e should be checked If the cable is cut damaged or immersed in water stop using it immediately and remove the trace heating This also applies if there are any signs of carbonisation or tearing or if f...

Page 10: ...F r Ihre Notizen Notes...

Page 11: ...F r Ihre Notizen Notes...

Page 12: ...stell und Service Hotline Fon 0800 6 343662 Fax 0800 6 343292 D Free service number Phone 00 800 63 436624 Fax 00 800 63 432924 GB OEG GmbH Industriestra e 1 D 31840 Hess Oldendorf info oeg net www oe...

Reviews: