Pipe heat tracing
GB
6
This product has been developed and manufactured for the sole use of preventing water pipes
from freezing. Improper installation, application and / or maintenance of the trace heating can re-
sult in fire, electric shock and / or freezing of pipes.
Warning: Use only on water supply pipes and according to these instructions. The minimum pipe
length is 2 m.
General information
Selection of the heating cable
Mounting notes
Mounting instructions
1
.0
2
.0
3
.0
4
.0
Tools and material required
Mounting to metal water pipes
Mounting to plastic water pipes
Maintenance
4.1
4.2
4.3
5
.0
7
8
9
9
6
6
7
7
Table of Contents
1
.0
General information
The anti-freeze heating cable should be long enough to run along the bottom of horizontal pipes or
along the weather-side of vertical pipes (including all valves) without crossing or spiralling.
To ensure a good thermal transfer, the heating cable should fit closely over the entire length of the
pipe. Never use a cable that is longer than the pipe to be protected.