background image

Specifications 

Power adapter: 
 

primary 

 

 

230 V AC 

 

secondary   

 

6 V DC / 400 mA 

Charging current of rechargeable battery in pager: 
 

accelerated charging (LX2 / LX4) 

appr.  100 / 350 mA 

 

trickle charging   

appr. 

2,5 mA 

Terminal for external alarm (CHARGER only): 
 

contact relay 

 

30 V DC / 1 A 

 

power supply for   

appr. 6 V DC / max. 175 mA 

  

external alarm system 

 

AF-port frequency 

appr. 1,2 kHz 

Terminal for external antenna (CHARGER only): 

BNC 

Indicators: 
 

alert light (CHARGER only) 

red 

 

charge indicator   

green / yellow 

Dimensions: 

appr. 106 mm / 93 mm / 60 mm 

Charger LX2 / LX4 with audible alert, only: 
 

integrated alert sound transducer 

appr. 2,3 kHz 

 

 

 

 

 

 

 

Oelmann Elektronik GmbH  

2008 

Content is subject to change without notice! 
B241.02.01 

 

Service / Repair: 

 

Oelmann Elektronik GmbH 
Allerfeldstr.17, 31832 Springe, DEUTSCHLAND 
Phone: +49  5045 9105-0  

  Fax: +49  5045 9105-79

 

 

Summary of Contents for Standard Charger LX2

Page 1: ...Heimzusatz LX2 LX4 Standardlader LX2 LX4 Bedienungsanleitung...

Page 2: ...mzusatz der Technischen Richtlinie f r die digitale Funkalarmierung TR BOS Wichtige Hinweise Bei Missbrauch des Steckernetzteiles und des Ladeger tes drohen Gefahren f r Mensch und Ger t Das Ladeger t...

Page 3: ...r t nicht in die N he starker Magnetfelder bringen Lautsprecher Fernseher Monitor Wartung Pflege und Reparatur Das Ger t bedarf keiner besonderen Wartung Das Ger t nur mit einem feuchten Tuch reinigen...

Page 4: ...Alarmlampe nur Heimzusatz rot blinkend Meldeempf nger eingelegt Alarmierung erfolgt Ladekontroll Lampe gr n blitzend 30s Betriebsanzeige nach Einstecken des Steckernetzteils bzw Entnahme des Meldeempf...

Page 5: ...iche Steckdose stecken Ladekontroll Lampe blitzt zur Betriebskontrolle gr n 30s Alarmierung im Ladeger t Steckt der Meldeempf nger im Ladeger t so ist er automatisch auf Lauter Alarm eingestellt Vibra...

Page 6: ...nd des Akkus Nach Beendigung der kontrollierten Ladung schaltet das Ger t auf Erhaltungsladung Kontrollierte Ladung des Meldeempf nger Akkus Ladekontroll Lampe leuchtet gelb Erhaltungsladung des Melde...

Page 7: ...4 asymmetrischer NF Ausgang geschaltet bei Alarmierung f r Zusatzlautsprecher mit Endverst rker Hinweis Die L nge der Anschlussleitungen zur externen Signalisiereinrichtung darf 3 m nicht berschreiten...

Page 8: ...DC max 175 mA externe Signalisiereinrichtung NF Ausgangsfrequenz ca 1 2 kHz Anschluss externe Antenne nur Heimzusatz BNC Kontroll Lampen Alarmlampe nur Heimzusatz rot Ladekontroll Lampe gr n gelb Ma e...

Page 9: ...CHARGER LX2 LX4 STANDARD CHARGER LX2 LX4 User Guide...

Page 10: ...the pager the CHARGER LX2 LX4 operates according to the digital POCSAG signalling scheme TR BOS Important safety information Misuse of the power adapter and the charger can put humans and device in da...

Page 11: ...inging the charger close to sources of heat Keep your charger away from strong magnetic fields speakers TV sets monitors etc Maintenance and repair Your charger does not require any special maintenanc...

Page 12: ...only red intermittent light pager inside the charger having received a message Charge indicator green flashing 30s indicates connection of the power adapter to the mains or removing of the pager yell...

Page 13: ...to an easily accessible main socket Charge indicator lamp flashes green 30s Receiving messages while charging When the pager is inside the charger the alert mode changes automatically to audible alert...

Page 14: ...l of the rechargeable battery used When charging is completed the charger will automatically switch to trickle charging charging of the pager charge indicator yellow on trickle charging of the pager c...

Page 15: ...tem pin 4 asymmetrical AF terminal for external speakers with power amplifier Important The length of the connecting cords between the charger and external alarm should not exceed 3m Declaration of co...

Page 16: ...A external alarm system AF port frequency appr 1 2 kHz Terminal for external antenna CHARGER only BNC Indicators alert light CHARGER only red charge indicator green yellow Dimensions appr 106 mm 93 mm...